McQuay MDS030AR Applications Manual page 47

Multi-digital scroll units
Hide thumbs Also See for MDS030AR:
Table of Contents

Advertisement

Model MDS260BR(Master Unit)
R
S
T
KM1
KM2
KM3
OL1
OL2
OL3
18
19
21 22
T2
T2
T1
T3
T1
T3
M
M
~
~
Shaft heater
Shaft heater
Digital compressor
Constant-speed compressor
Description of components and parts :
Symbol
Description
Symbol
DB3A
Phase-loss/reverse protector
FU
Fuse
4WV
Four-way valve
EXV1
System electronic expansion valve 1
KM
Contactor
EXV4
Over cooling electronic expansion valve 4
HP
High-pressure switch
PMW
Solenoid valve
LPT
Low -pressure sensor
OL
Overload protector
HPT
High-pressure sensor
TR
Transformer
Model MDS280/300BR(Master Unit)
380V/3N~/50Hz
R
S
T
KM1
KM2
KM3
OL1
OL2
OL3
18
19
T2
T2
T2
T1
T3
T1
T3
T1
T3
M
M
M
~
~
~
Shaft heater
Shaft heater
Shaft heater
Constant-speed
Constant-speed
Digital compressor
compressor 1
compressor 2
Description of components and parts :
Symbol
Description
Symbol
DB3A
Phase-loss/reverse protector
FU
Fuse
4WV
Four-way valve
EXV1
System electronic expansion valve
KM
Contactor
EXV4 Over cooling electronic expansion valve 4
High-pressure switch
HP
PMW
Solenoid valve
Low -pressure sensor
LPT
OL
Overload protector
HPT
High-pressure sensor
Transformer
TR
L
FU
T
71
S
81
DB3A
R
N
KM4
OL4
23
24 25 26
L1
M
~
Fan motor
Description
Overload protection settings :
OL1
OL2
OL3
OL4
14.0A
14.0A
3.3A
1.8A
DIP switch settings :
S1.1
S1.2
S2.1
S2.2
S2.3
OFF
OFF
ON
OFF
ON
L
FU
T
71
S
DB3A
81
R
N
KM4
KM5
OL4
OL5
20
21 22
23
24 25 26
M
~
Fan motor
Description
Overload protection settings :
OL1
OL2
OL3
14.0
14.0
14.0
DIP switch settings :
Model
S1.1
MDS280BR
OFF
MDS300BR
OFF
MDS320BR
OFF
Design & installation Guide For McQuay MDS Multi System
HI-1
TH7
TH6
TH5
TH3
TH12
TH11
LOW-I
TR
V1+
BLACK
V1-
V2+
WHITE
V2-
FIX3-OL
FIX2-OL
OL1
12
FIX1-OL
MDS-P
13
OL2
DIG-OL
LP
S1
HP
15 OL3
16
OL4
17
HP
N
L
J18
J1
1
2
4
KM3 KM4
3
5
PMW
KM4
KM3
Notes:
1: -----------Field wiring
Factory wiring
2: --------------
3: S1.3~S1.8 set the number of indoor units. S2.1 sets the
unit as a master/slave. For details of S2.4~S2.8.
S3.1
S3.2
S3.3
S3.4
ON
OFF
OFF OFF
LOW-I
HI-1
TH7
TH6
TH5
TR
V1+
BLACK
V1-
V2+
WHITE
V2-
FIX3-OL
OL2
12
FIX2-OL
OL1
13
MDS-P
FIX1-OL
14
OL3
DIG-OL
LP
L1
HP
15 OL4
16
OL5
17
HP
N
L
J18
J1
1
2
KM4
3
PMW
OL4
OL5
3.3A
1.8A
S1.2
S2.1
S2.2
S2.3 S3.1
S3.2
S3.3
S3.4
OFF
ON
OFF
ON
ON
OFF
OFF
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
OFF
ON
ON
LPT
HPT
1 2
3
1
2
3
TH10 TH9
TH8
TH4
TH2
TH1
LOW-U
HI-U
MDS-M
30
Connecting the indoor unit
31
32
Connecting central control system
33
S2
S3
EXV1
EXV4
7
10
11
EXV1
EXV4
4WV
KM1
KM2
LPT
HPT
1 2
1
2
3
3
TH3
TH12
TH11
TH10 TH9
TH8
TH4
TH2
TH1
LOW-U
HI-U
MDS-M
30
31
Connecting the indoor unit
32
Connecting central control system
33
S1
S2
S3
EXV1
EXV4
4
7
8
10
11
KM5
EXV1
EXV4
5
KM5
KM4
4WV
KM2
KM1
KM3
Notes:
1: -----------Field wiring
2: --------------
Factory wiring
3: S1.3~S1.8 set the number of indoor units. S2.1 sets the
unit as a master/slave. For details of S2.4~S2.8.
-47-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents