McQuay MDS030AR Applications Manual page 45

Multi-digital scroll units
Hide thumbs Also See for MDS030AR:
Table of Contents

Advertisement

Model MDS180B
380V/3N~/50Hz
R
S
T
KM1
KM2
KM3
OL1
OL2
OL3
T2
T2
T2
T1
T3
T1
T3
T1
T3
M
M
M
~
~
~
Constant-speed
Constant-speed
Digital compressor
compressor 1
compressor 2
Description of components and parts :
Symbol
Description
Symbol
Phase-loss/reverse protector
DB3A
FU
Fuse
EXV4
Over cooling electronic expansion valve 4
4WV
Four-way valve
KM
Contactor
PMW
Solenoid valve
High-pressure switch
HP
OL
Overload protector
Low -pressure sensor
LPT
HPT
High-pressure sensor
Transformer
TR
Model MDS180BR
380V/3N~/50Hz
R
S
T
N
KM1
KM2
KM3
OL1
OL2
OL3
28
29
30
T2
T2
T2
T3
T1
T3
T1
T3
T1
M
M
M
~
~
~
Shaft heater
Shaft heater
Shaft heater
Constant-speed
Constant-speed
Digital compressor Fan motor 1
compressor 1
compressor 2
Description of components and parts :
Symbol
Description
Symbol
DB3A
Phase-loss/reverse protector
FU
Fuse
4WV
Four-way valve
EXV1
System electronic expansion valve 1
KM
Contactor
EXV2
System electronic expansion valve 2
HP
High-pressure switch
EXV4
Over cooling electronic expansion valve 4
LPT
Low -pressure sensor
PMW
Solenoid valve
HPT
High-pressure sensor
OL
Overload protector
TR
Transformer
FU
T
71
S
81
R
N
DB3A
KM4
KM5
KM6
KM7
OL4
OL5
OL6
OL7
32 33
34
35 36 37
38
39
40
41
42
43
M
M
~
~
Fan motor 1
Fan motor 2
Description
Overload protection settings :
OL1
OL2
OL3
OL4
14.0
14.0
14.0
1.9A
DIP switch settings :
S1.1
S1.2
S2.2
S2.3
OFF
ON
OFF
ON
FU
71
T
S
81
R
N
DB3A
KM4
KM5
KM6
KM7
OL4
OL5
OL6
OL7
L1
32 33
34
35 36 37
38
39
40
41
42
43
M
M
~
~
Fan motor 2
Description
Overload protection settings :
OL1
OL2
OL3
OL4
OL5
14.0
14.0
14.0
1.9A
0.67A
DIP switch settings :
S1.1
S1.2
S2.2
S2.3
S3.1
OFF
OFF
OFF
ON
OFF
Design & installation Guide For McQuay MDS Multi System
L
TR
LOW-I
HI-1
TH6
TH3
V1+
TH7
TH5
TH12
BLACK
V1-
V2+
WHITE
V2-
MDS-E
FIX3-OL
OL2
12
FIX2-OL
OL1
13
FIX1-OL
14
OL3
DIG-OL
LP
L1
HP
OL4
16
OL5
17
15
OL6 18
OL7
19
HP
N
L
J1
20
21
22
23
1
KM5
KM4
KM7
KM6
24
25
26
27
KM4
KM5
KM6
KM7
PMW
Notes:
OL5
OL6
OL7
1: -----------Field wiring
2: --------------
0.67A
1.9A
0.67A
3: S1.3~S1.8 set the number of indoor units. S2.1 sets the
unit as a master/slave. For details of S2.4~S2.8.
S3.1
S3.2
S3.3
S3.4
OFF
ON
OFF
OFF
L
EXV2
TR
LOW-I
HI-1
TH6
V1+
TH7
TH5
BLACK
V1-
V2+
WHITE
V2-
MDS-E
FIX3-OL
12
OL2
FIX2-OL
13
OL1
FIX1-OL
14
OL3
DIG-OL
LP
16
HP
15 OL4
OL5
17
OL6 18
OL7
19
HP
N
L
J1
20
21
22
23
1
KM5
KM4
KM7
KM6
24
25
26
27
KM4
KM5
KM6
KM7
PMW
Notes:
1: -----------Field wiring
OL6
OL7
Factory wiring
2: --------------
1.9A
0.67A
3: S1.3~S1.8 set the number of indoor units. S2.1 sets the
unit as a master/slave. For details of S2.4~S2.8.
S3.2
S3.3
S3.4
ON
OFF
OFF
LPT
HPT
1
2
3
1
2
3
TH4
TH1
TH11
TH9
LOW-U HI-U
TH10
TH8
TH2
MDS-M
45
46
Connecting the indoor unit
47
Connecting central control system
48
S1
S2
S3
MDS-P
EXV1
EXV4
2
5
7
10
4WV2
KM2
KM1
KM3
EXV4
Factory wiring
LPT
HPT
1
2
1
2
3
3
TH3
TH11
TH9
TH4
TH1
LOW-U HI-U
TH12
TH10
TH8
TH2
MDS-M
45
46
Connecting the indoor unit
47
48
Connecting central control system
S1
S2
S3
MDS-P
EXV1
EXV4
2
3
5
7
10
4WV2
4WV1
KM2
KM1
KM3
EXV1
EXV4
-45-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents