Ducted split systems

Advertisement

MDB - 2004
Ducted Split Systems
Models: MDB 075-750B
MDB 125-150C
MDB 075-500BR
MDB 125CR

Advertisement

Table of Contents
loading

Summary of Contents for McQuay MDB075B

  • Page 1 MDB - 2004 Ducted Split Systems Models: MDB 075-750B MDB 125-150C MDB 075-500BR MDB 125CR...
  • Page 2: Table Of Contents

    "McQuay" is a registered trademark of McQuay International. All rights reserved throughout the world. ©2003 McQuay International "Bulletin illustrations cover the general appearance of McQuay International products at the time of publication and we reserve the right to make changes in design and construction at any time without notice."...
  • Page 3: Nomenclature System

    The conditioned air can be effectively distributed to every corner of the room through the ducting and this ensure a more pleasant environment for comfort living. Flexibility Of Air Supply McQuay MDB series using belt driven fan such as that the air volume and static required can be adjusted according to the requirement. This flexibility allow for wider application.
  • Page 4: General Specifications

    General Specifications Unit The casing is constructed with electro-galvanised mild steel sheet which provides a rigid cabinet. The internal components are easily accessible by removing the front panel. The finishing of the casing is a long-lasting epoxy polyester powder coating. Condenser Coil Each coil consists of staggered rows of 3/8"...
  • Page 5 2. OPERATING GUIDE 2.1 ON/OFF key Press once to start the air conditioning unit. Press again to stop the unit. The operation lamp next to the key lights up and goes off respectively when the unit is running or not running. Caution : In the case when the ON/OFF key is pressed immediately after the operation is stopped, the unit will not restart until 3 minutes later to protect the compressor.
  • Page 6 Error Error Possible fault Possible fault code code Require manual reset (possible causes) Indoor coil sensor 4 short Compressor 1 high temperature (overload) Indoor coil sensor 1 open Compressor 2 high temperature(overload) Indoor coil sensor 2 open Compressor 3 high temperature(overload) Indoor coil sensor 3 open Compressor 4 high temperature(overload) Indoor coil sensor 4 open...
  • Page 7: Specifications

    Specifications Cooling only MDB075B MDB100B MODEL INDOOR UNIT OUTDOOR UNIT MMC075B MMC075C MMC100B MMC100C TOTAL OUTDOOR Btu/h 75,000 100,000 COOLING 35 °CDB kcal/h 18,900 25,200 CAPACITY 21,975 29,300 MATERIAL ELECTRO GALVANIZED MILD STEEL EPOXY POLYESTER POWDER COATING CASING FINISHING INSULATION...
  • Page 8: Cooling Only

    Cooling only MODEL INDOOR UNIT MDB125B MDB125C MDB150B2 MDB150C2 OUTDOOR UNIT MMC125B MMC075B x 2 MMC075C x 2 MMC075B x 2 MMC075C x 2 TOTAL OUTDOOR Btu/h 125,000 125,000 150,000 150,000 COOLING 35 °CDB kcal/h 37,800 37,800 31,500 31,500 CAPACITY 43,950 43,950 36,625...
  • Page 9 Cooling only MODEL INDOOR UNIT MDB150B1 MDB150C1 MDB200B2 MDB250B2 OUTDOOR UNIT MMC150C MMC100B x 2 MMC100C x 2 MMC125B x 2 TOTAL OUTDOOR Btu/h 150,000 150,000 200,000 250,000 COOLING 35 °CDB kcal/h 37,800 37,800 50,400 63,000 CAPACITY 43,950 43,950 58,600 73,250 MATERIAL ELECTRO GALVANIZED MILD STEEL...
  • Page 10 Cooling only MDB300B3 MDB350B3 MODEL INDOOR UNIT MDB300B2 OUTDOOR UNIT MMC100B x 3 MMC100C x 3 MMC150C x 2 MMC100B x 1 MMC125B x 2 TOTAL OUTDOOR Btu/h 300000 300000 350000 75600 88200 COOLING 35 °CDB kcal/h 75600 CAPACITY 87900 87900 102550 NOMINAL TOTAL POWER...
  • Page 11 Cooling only MDB400B4 MODEL INDOOR UNIT MDB450B3 MDB500B4 MDB600B4 MDB750B5 OUTDOOR UNIT MMC100B x 4 MMC100C x 4 MMC150C x 3 MMC125B x 4 MMC150C x 4 MMC150C x 5 400,000 TOTAL OUTDOOR Btu/h 450,000 500,000 600,000 750,000 100,800 COOLING 35 °CDB kcal/h 113,400...
  • Page 12 Heatpump MODEL INDOOR UNIT MDB075BR MDB100BR MDB125CR MDB150BR2 MDB200BR2 OUTDOOR UNIT MMC075CR MMC100BR MMC125BR MMC075CR X2 MMC100BR X2 NORMINAL Btu/h 74000 98800 116000 148000 197600 COOLING kcal/h 18650 24899 29234 37298 49798 CAPACITY 21688 28957 33998 43376 57913 TOTAL Btu/h 74000 96560 120000...
  • Page 13 Heatpump MDB350BR3 MODEL INDOOR UNIT MDB250BR2 MDB300BR3 MDB400BR4 MDB500BR4 OUTDOOR UNIT MMC125BR x 2 MMC100BR x 3 MMC100BR x 1 MMC125BR x 2 MMC100BR x 4 MMC125BR x 4 330800 NORMINAL Btu/h 232000 296400 395200 464000 COOLING kcal/h 58468 74698 83367 99597 116935...
  • Page 14 Heatpump 220V-60 Hz INDOOR UNIT MDB075BR MDB100BR MDB125CR MODEL OUTDOOR UNIT MMC075CR MMC100BR MMC125BR TOTAL Btu/h 74,000 98,800 116,000 COOLING kcal/h 18,650 24,898 29,232 CAPACITY 21,688 28,957 34,000 TOTAL Btu/h 74,000 96,500 120,000 HEATING kcal/h 18,650 24,318 30,240 CAPACITY 21,688 28,283 35,170 NOMINAL TOTAL POWER (COOLING)
  • Page 15 Heatpump 220V-60 Hz MODEL INDOOR UNIT MDB150BR2 MDB200BR2 MDB250BR2 OUTDOOR UNIT MMC075CR x2 MMC100BR x2 MMC125BR x2 TOTAL Btu/h 148,000 197,600 232,000 COOLING kcal/h 37,296 49,795 58,464 CAPACITY 43,376 57,913 67,995 TOTAL Btu/h 148,000 193,000 240,000 HEATING kcal/h 37,296 48,636 60,480 CAPACITY 43,376...
  • Page 16 Heatpump 220V-60 Hz MODEL INDOOR UNIT MDB300BR3 MDB350BR3 MDB400BR4 MDB500BR4 OUTDOOR UNIT MMC100BR x3 MMC100BR x1 MMC125BR x2 MMC100BR x4 MMC125BR x4 TOTAL Btu/h 296400 330,800 395200 464000 COOLING kcal/h 74693 83,362 99590 116928 CAPACITY 86870 96,952 115826 135991 TOTAL Btu/h 289500 336,500...
  • Page 17 Heatpump 460V-60 Hz INDOOR UNIT MDB075BR MDB100BR MDB125CR MODEL OUTDOOR UNIT MMC075CR MMC100BR MMC125BR TOTAL Btu/h 74,000 98,800 116,000 COOLING kcal/h 18,650 24,898 29,232 CAPACITY 21,688 28,957 34,000 TOTAL Btu/h 74,000 96,500 120,000 HEATING kcal/h 18,650 24,318 30,240 CAPACITY 21,688 28,283 35,170 NOMINAL TOTAL POWER (COOLING)
  • Page 18 Heatpump 460V-60 Hz MODEL INDOOR UNIT MDB150BR2 MDB200BR2 MDB250BR2 OUTDOOR UNIT MMC075CR x2 MMC100BR x2 MMC125BR x2 TOTAL Btu/h 148,000 197,600 232,000 COOLING kcal/h 37,296 49,795 58,464 CAPACITY 43,376 57,913 67,995 TOTAL Btu/h 148,000 193,000 240,000 HEATING kcal/h 37,296 48,636 60,480 CAPACITY 43,376...
  • Page 19 Heatpump 460V-60 Hz INDOOR UNIT MDB300BR3 MDB350BR3 MDB400BR4 MDB500BR4 MODEL OUTDOOR UNIT MMC100BR x3 MMC100BR x1 MMC125BR x2 MMC100BR x4 MMC125BR x4 TOTAL Btu/h 296400 330,800 395200 464000 COOLING kcal/h 83,362 74693 99590 116928 CAPACITY 96,952 86870 115826 135991 TOTAL Btu/h 289500 336,500...
  • Page 20: Performance Characteristics

    Performance Characteristics 50Hz R22 SPECIFICATIONS COOLING MODEL MODEL : MDB075B vs. MMC075B (cooling capacity) Indoor DB Indoor WB Capacity Outdoor DB, °C °C °C 19.4 25.0 30.0 35.0 40.0 46.0 26.7 13.9 20.452 19.432 18.521 17.610 16.700 15.607 20.452 19.432 18.521...
  • Page 21 MODEL : MDB150B1/B2 vs. MMC150C/075B x 2 (cooling capacity) Outdoor DB, °C Indoor DB Indoor WB Capacity °C °C 19.4 25.0 30.0 35.0 40.0 46.0 26.7 13.9 39.015 37.373 35.906 34.440 32.973 31.213 36.472 35.365 34.377 33.388 32.400 31.213 15.0 41.479 39.635 37.990...
  • Page 22 MODEL : MDB250B2 vs. MMC125B x 2 (cooling capacity) Outdoor DB, °C Indoor DB Indoor WB Capacity °C °C 19.4 25.0 30.0 35.0 40.0 46.0 26.7 13.9 59.640 58.036 56.604 55.173 53.741 52.022 59.640 58.036 56.604 55.173 53.741 52.022 15.0 67.492 64.369 61.581...
  • Page 23 MODEL : MDB450B3 vs. MMC150C x 3 (cooling capacity) Outdoor DB, °C Indoor DB Indoor WB Capacity °C °C 19.4 25.0 30.0 35.0 40.0 46.0 26.7 13.9 117.353 112.361 107.904 103.446 98.989 93.64 111.895 108.052 104.621 101.189 97.758 93.64 15.0 122.687 117.822 113.478...
  • Page 24: Capacity Kw

    131.088 124.825 117.309 24.0 308.165 288.500 270.942 253.384 235.826 214.757 143.041 134.021 125.967 117.913 109.859 100.194 Indoor MDB075B MDB100B MDB125B MDB150B1 MDB150B2 Outdoor MMC075B MMC100B MMC125B MMC075B x 2 MMC075B x 2 Bypass Factor 0.47 0.51 0.53 0.53 0.53 Indoor...
  • Page 25 50Hz R22 HEATPUMP MODEL MODEL : MDB075BR vs. MMC075CR Outdoor DB, °C Indoor DB Indoor WB Capacity °C °C 19.4 25.0 30.0 35.0 40.0 46.0 26.7 13.9 19.526 18.657 17.881 17.105 16.330 15.399 19.526 18.657 17.881 17.105 16.330 15.399 15.0 21.374 20.171 19.096...
  • Page 26 MODEL : MDB150BR2 vs. MMC075CR x 2 Outdoor DB, °C Indoor DB Indoor WB Capacity °C °C 19.4 25.0 30.0 35.0 40.0 46.0 26.7 13.9 38.238 36.672 35.273 33.874 32.476 30.797 38.238 36.672 35.273 33.874 32.476 30.797 15.0 42.097 39.828 37.801 35.775 33.748...
  • Page 27 MODEL : MDB300BR3 vs. MMC100BR x 3 Outdoor DB, °C Indoor DB Indoor WB Capacity °C °C 19.4 25.0 30.0 35.0 40.0 46.0 26.7 13.9 54.839 56.279 57.564 58.850 60.135 61.678 54.839 56.279 57.564 58.850 60.135 61.678 15.0 67.904 66.665 65.559 64.454 63.348...
  • Page 28 MODEL : MDB300BR3 vs. MMC100BR x 3 Outdoor DB, °C Indoor DB Indoor WB Capacity °C °C 19.4 25.0 30.0 35.0 40.0 46.0 26.7 13.9 54.839 56.279 57.564 58.850 60.135 61.678 54.839 56.279 57.564 58.850 60.135 61.678 15.0 67.904 66.665 65.559 64.454 63.348...
  • Page 29 50Hz R22 HEATPUMP MODEL MODEL : MDB075BR vs. MMC075CR Outdoor WB°C Indoor DB Capacity °C -9.0°C -5.0°C 6.0°C 12.0°C 15.0°C 18.3°C 13.358 15.933 23.016 26.879 28.811 30.936 15.0°C 13.358 15.933 23.016 26.879 28.811 30.936 13.140 15.790 22.573 26.640 28.554 30.660 17.0°C 13.140 15.790...
  • Page 30 MODEL : MDB150BR2 vs. MMC075CR x 2 Outdoor WB°C Indoor DB Capacity °C -9.0°C -5.0°C 6.0°C 12.0°C 15.0°C 18.3°C 26.715 31.866 46.032 53.759 57.622 61.871 15.0°C 26.715 31.866 46.032 53.759 57.622 61.871 26.280 31.581 45.147 53.279 57.108 61.320 17.0°C 26.280 31.581 45.147 53.279...
  • Page 31 MODEL : MDB300BR3 vs. MMC100BR x 3 Outdoor WB°C Indoor DB Capacity °C -9.0°C -5.0°C 6.0°C 12.0°C 15.0°C 18.3°C 51.204 59.293 81.535 93.667 99.733 106.406 15.0°C 51.204 59.293 81.535 93.667 99.733 106.406 50.684 58.761 82.657 92.832 98.844 105.458 17.0°C 50.684 58.761 82.657 92.832...
  • Page 32 MODEL : MDB500BR4 vs. MMC125BR x 4 Outdoor WB°C Indoor DB Capacity °C -9.0°C -5.0°C 6.0°C 12.0°C 15.0°C 18.3°C 90.764 105.144 144.690 166.261 177.047 188.911 15.0°C 90.764 105.144 144.690 166.261 177.047 188.911 89.833 104.201 143.354 164.778 175.468 187.227 17.0°C 89.833 104.201 143.354 164.778...
  • Page 33: Power Table

    Power Table MODEL : MDB075B vs MMC075C Outdoor DB, °C Indoor WB °C 19.4 25.0 30.0 35.0 40.0 46.0 50.0 52.0 54.0 13.9 6,153 6,735 7,254 7,773 8,292 8,915 9,331 9,538 9,746 15.0 6,220 6,817 7,351 7,884 8,418 9,058 9,485...
  • Page 34 MODEL : MDB150C1 vs MMC150C Outdoor DB, °C Indoor WB °C 19.4 25.0 30.0 35.0 40.0 46.0 50.0 52.0 54.0 13.9 13,200 14,366 15,407 16,448 17,489 18,738 19,570 19,987 20,403 15.0 13,311 14,523 15,605 16,687 17,770 19,068 19,934 20,367 20,799 16.7 13,483 14,766...
  • Page 35 MODEL : MDB500B4 vs MMC125B x 4 Outdoor DB, °C Indoor WB °C 19.4 25.0 30.0 35.0 40.0 46.0 50.0 52.0 54.0 13.9 39,160 43,079 46,579 50,078 53,578 57,777 60,577 61,977 63,377 15.0 39,671 43,593 47,095 50,597 54,099 58,301 61,102 62,503 63,904 16.7...
  • Page 36: Drive Package Selection Example

    Drive Package Selection Example The following are the design requirements for MDB125B unit: Model: MDB125B Supply Air Quantity 4500 External Static Pressure mmAq Step 1: From the blower curve (at 4500 CFM), Standard operating system; Total Static Pressure 26.5 mmAq Internal Static Pressure 17.5 mmAq...
  • Page 37 The following table summarizes the pulley data, motor size used for the MDB series, as manufactured: Model Motor pulley, Dm Blower pulley, Db 50 Hz 60 Hz 50 Hz 60 Hz V-pulley Taper # V-pulley Taper # V-pulley Taper # V-pulley Taper # (in.)
  • Page 38: Blower Performance Curves

    Blower Performance Curves MDB 075B BLOWER PERFORMANCE CURVE...
  • Page 39 MDB 100B BLOWER PERFORMANCE CURVE...
  • Page 40 MDB 125B BLOWER PERFORMANCE CURVE...
  • Page 41 MDB 125C BLOWER PERFORMANCE CURVE...
  • Page 42 MDB 150B BLOWER PERFORMANCE CURVE...
  • Page 43 MDB 150C BLOWER PERFORMANCE CURVE...
  • Page 44 MDB 200B BLOWER PERFORMANCE CURVE...
  • Page 45 MDB 250B BLOWER PERFORMANCE CURVE...
  • Page 46 MDB 300B BLOWER PERFORMANCE CURVE...
  • Page 47 MDB 350B BLOWER PERFORMANCE CURVE...
  • Page 48 MDB 400B BLOWER PERFORMANCE CURVE...
  • Page 49 MDB 450B BLOWER PERFORMANCE CURVE...
  • Page 50 MDB 500B BLOWER PERFORMANCE CURVE...
  • Page 51 MDB 600B BLOWER PERFORMANCE CURVE...
  • Page 52 MDB 750B BLOWER PERFORMANCE CURVE...
  • Page 53: Outlines And Dimensions (Indoor)

    Outlines And Dimensions (Indoor) MODEL: MDB 075/ 100 B/BR MODEL: MDB 125C (HORIZONTAL AIR DISCHARGE ONLY)
  • Page 54 MODEL: MDB 150B1 [STANDARD: HORIZONTAL AIR DISCHARGE; OPTIONAL: VERTICAL AIR DISCHARGE] MODEL: MDB 150B2/BR2 [STANDARD: HORIZONTAL AIR DISCHARGE; OPTIONAL: VERTICAL AIR DISCHARGE)
  • Page 55 MODEL: MDB 150C1 (HORIZONTAL AIR DISCHARGE ONLY) MODEL: MDB 200B2/BR2 [STANDARD: VERTICAL AIR DISCHARGE; OPTIONAL: HORIZONTAL AIR DISCHARGE]...
  • Page 56 MODEL: MDB 250/300 B2/BR2 [STANDARD: VERTICAL AIR DISCHARGE; OPTIONAL: HORIZONTAL AIR DISCHARGE] MODEL: MDB 300B3/BR3 [STANDARD: VERTICAL AIR DISCHARGE; OPTIONAL: HORIZONTAL AIR DISCHARGE]...
  • Page 57 MODEL: MDB 350B3/BR3 [STANDARD: VERTICAL AIR DISCHARGE; OPTIONAL: HORIZONTAL AIR DISCHARGE] MODEL: MDB 400 / 500 B4/BR4 [STANDARD: VERTICAL AIR DISCHARGE; OPTIONAL HORIZONTAL AIR DISCHARGE]...
  • Page 58 MODEL: MDB 600B4 [STANDARD: VERTICAL AIR DISCHARGE; OPTIONAL: HORIZONTAL AIR DISCHARGE] *CAN CUSTOMIZE TO HORIZONTAL OR VERTICAL AIR DISCHARGE; NOT CONVERTIBLE AT FIELD. MODEL: MDB 750B5 [STANDARD: VERTICAL AIR DISCHARGE; OPTIONAL: HORIZONTAL AIR DISCHARGE] *CAN CUSTOMIZE TO HORIZONTAL OR VERTICAL AIR DISCHARGE; NOT CONVERTIBLE AT FIELD.
  • Page 59: Outlines And Dimensions (Outdoor)

    Outlines And Dimensions (Outdoor) MODEL: MMC 075B, 100/125 B (STANDARD VERTICAL AIR DISCHARGE) MODEL: MMC 075B, 100/125 B (OPTIONAL HORIZONTAL AIR DISCHARGE)
  • Page 60 MODEL: MMC 075C/CR MODEL: MMC 100C...
  • Page 61 MODEL: MMC 125BR / 150C ( STANDARD : VERTICAL DISCHARGE – NON CONVERTIBLE )
  • Page 62: Wiring Diagrams (Cooling)

    Wiring Diagrams (Cooling) MODEL : MDB 075B – MMC 075C Important note : A manual reset circuit must be provided at the field supplied external starter board for all protective devices. Note : 1) For export spec. 2) With U1.4 SLM...
  • Page 63 MODEL : MDB 075B – MMC 075B MDB 100B – MMC 100B / 100C Important note : A manual reset circuit must be provided at the field supplied external starter board for all protective devices. Note : 1) For export spec. 2) With U1.4 SLM...
  • Page 64 MODEL : INDOOR - MDB 075B (WITH U1.4 CCT SLM3 HANDSET) OUTDOOR – MMC 075B (WITH PHASE PROTECTOR/AUTO RESET HI/LO PRESSURE SWITCH) MODEL : INDOOR - MDB 075B (WITH U1.4 CCT SLM3 HANDSET) OUTDOOR – MMC 075C (WITH PHASE PROTECTOR/AUTO RESET HI/LO PRESSURE SWITCH)
  • Page 65 MODEL : INDOOR - MDB 100B (WITH U1.4 CCT SLM3 HANDSET) OUTDOOR – MMC 100B (WITH PHASE PROTECTOR/AUTO RESET HI/LO PRESSURE SWITCH) MODEL : INDOOR - MDB 125C (WITH U125-SB SLM HANDSET) OUTDOOR – MMC 125B (WITH PHASE PROTECTOR/AUTO RESET HI/LO PRESSURE SWITCH)
  • Page 66 MODEL : INDOOR - MDB 150C1 (WITH U125-SB SLM HANDSET) OUTDOOR – MMC 150C (WITH PHASE PROTECTOR/AUTO RESET HI/LO PRESSURE SWITCH) MODEL : INDOOR - MDB 150B2 (WITH SEQUENTIAL CONTROLLER) OUTDOOR – MMC 075C x 2...
  • Page 67 MODEL : INDOOR - MDB 150B2/200B2/250B2 (WITH SEQUENTIAL CONTROLLER) OUTDOOR – MMC 075B x 2 / MMC 100B x 2 / MMC 125B x 2 MODEL : INDOOR - MDB 300B2 (WITH SEQUENTIAL CONTROLLER) OUTDOOR – MMC 150C x 2...
  • Page 68 MODEL : INDOOR - MDB 300B3 & MDB 350B3 (WITH SEQUENTIAL CONTROLLER) OUTDOOR – MMC 100B x 3 / MMC 100C x 3 & (MMC100B/C x 1 + MMC125B x 2) MODEL : INDOOR - MDB 450B3 (WITH SEQUENTIAL CONTROLLER) OUTDOOR –...
  • Page 69 MODEL : INDOOR - MDB 400B4 & MDB 500B4 (WITH SEQUENTIAL CONTROLLER) OUTDOOR – MMC 100B x 4 & MMC 125B x 4...
  • Page 70 MODEL : INDOOR - MDB 600B4 (WITH SEQUENTIAL CONTROLLER) OUTDOOR – MMC 150C x 4...
  • Page 71 MODEL : INDOOR - MDB 750B5 (WITH MAGNETIC CONTACTOR) OUTDOOR – MMC 150C x 5...
  • Page 72: Wiring Diagrams (Heatpump)

    Wiring Diagrams (Heatpump) INDOOR (EXPORT) MODEL : MDB 075/100BR (C3.0B) MODEL : MDB 125CR (EXPORT)
  • Page 73 MODEL : MDB 150/ 200/ 250 BR2 (EXPORT) MODEL : MDB 300/ 350 BR3 (EXPORT)
  • Page 74 MODEL : MDB 400/ 500 BR4 (EXPORT)
  • Page 75 OUTDOOR (EXPORT) MODEL : MMC 075CR / 100BR (FOR SEQUENTIAL CONTROLLER) – VERSION 1 Note : With auto pressure control DANFOSS magnetic contactor Headline outdoor fan motor (single phase) MODEL : MMC 125BR (EXPORT) (FOR SEQUENTIAL CONTROLLER) – VERSION 1 Note : With auto pressure control DANFOSS magnetic contactor...
  • Page 76 OUTDOOR (HEATPUMP) MODEL : MMC 075CR / 100BR (FOR SEQUENTIAL CONTROLLER WITH PHASE PROTECTOR AND DISCHARGE THERMOSTAT) – VERSION 2 Note : - With auto pressure control DANFOSS magnetic contactor - Headline outdoor fan motor (single phase) MODEL : MMC 125BR (FOR SEQUENTIAL CONTROLLER WITH PHASE PROTECTOR AND DISCHARGE THERMOSTAT) –...
  • Page 77 MODEL : INDOOR - MDB 075BR (WITH U1.4 CCT SLM3 HANDSET) OUTDOOR – MMC 075CR (WITH PHASE PROTECTOR/ DISCHARGE THERMOSTAT/ AUTO RESET HI/LO PRESSURE SWITCH) – VERSION 3 MODEL : INDOOR - MDB 100BR (WITH U1.4 CCT SLM3 HANDSET) OUTDOOR – MMC 100BR (WITH PHASE PROTECTOR/ DISCHARGE THERMOSTAT/ AUTO RESET HI/LO PRESSURE SWITCH) –...
  • Page 78 MODEL : INDOOR - MDB 125CR (WITH U125-SB CONTROLLER) OUTDOOR – MMC 125BR (WITH PHASE PROTECTOR/ DISCHARGE THERMOSTAT/ AUTO RESET HI/LO PRESSURE SWITCH) MODEL : INDOOR - MDB 150/200BR2 (WITH SEQUENTIAL CONTROLLER) OUTDOOR –MMC 075CR x 2 / MMC100BR x 2 (WITH PHASE PROTECTOR/ DISCHARGE THERMOSTAT/ AUTO RESET HI/LO PRESSURE SWITCH)
  • Page 79 MODEL : INDOOR - MDB 250BR2 (WITH SEQUENTIAL CONTROLLER) OUTDOOR – MMC 125BR x 2 (WITH PHASE PROTECTOR/ DISCHARGE THERMOSTAT/ AUTO RESET HI/LO PRESSURE SWITCH)
  • Page 80 MODEL : INDOOR - MDB 300 BR3 (WITH SEQUENTIAL CONTROLLER) OUTDOOR – MMC 100BR x 3 (WITH PHASE PROTECTOR/ DISCHARGE THERMOSTAT/ AUTO RESET HI/LO PRESSURE SWITCH)
  • Page 81 MODEL : INDOOR - MDB 350 BR3 (WITH SEQUENTIAL CONTROLLER) OUTDOOR – MMC 100BR x 1 / MMC125BR x 2 (WITH PHASE PROTECTOR/ DISCHARGE THERMOSTAT/ AUTO RESET HI/LO PRESSURE SWITCH)
  • Page 82 MODEL : INDOOR - MDB 400 BR4 (WITH SEQUENTIAL CONTROLLER) OUTDOOR – MMC 100BR x 4 (WITH PHASE PROTECTOR/ DISCHARGE THERMOSTAT/ AUTO RESET HI/LO PRESSURE SWITCH)
  • Page 83 MODEL : INDOOR - MDB 500 BR4 (WITH SEQUENTIAL CONTROLLER) OUTDOOR – MMC 125BR x 4 (WITH PHASE PROTECTOR/ DISCHARGE THERMOSTAT/ AUTO RESET HI/LO PRESSURE SWITCH)
  • Page 84: Refrigerant Circuit Diagram

    Refrigerant Circuit Diagram...
  • Page 90: Installation (Indoor)

    Installation (Indoor) Preliminary Site Survey a) Electrical supply and installation is to confirm to local authority’s (e.g. National Electricity Board) codes and regulations. b) Voltage supply fluctuation must not exceed +/- 10% of rated voltage. Electricity supply line must be independent of welding transformers which can cause supply fluctuation.
  • Page 91: Installation (Outdoor)

    Installation (Outdoor) Location For Installation Of The Condensing Units As condensing temperature rises, evaporating temperature rises and cooling capacity drops. In order to achieve maximum cooling capacity, the location selected should fulfill the following requirements:- Install the condensing (outdoor) unit in a way such that hot air distributed by the outdoor condensing unit cannot be drawn in again (as in the case of short circuit of hot discharge air).
  • Page 92 b) Ensure that there is no obstruction of air flow into or out of the unit. Remove obstacle which block air intake or discharge. c) The location must be well ventilated, so that the unit can draw and distribute plenty of air thus lowering the condensing temperature.
  • Page 93 Field Piping To ensure satisfactory operation and performance, the following points should be noted for the field piping arrangements of the complete refrigerant cycle. a) Liquid loops or oil traps must be provided according to the position of the outdoor and the indoor units (depending on whether the indoor unit is above or below the outdoor unit).
  • Page 94 Installation Clearance A) For MMC – B/BR series (Single/Multiple Condensing Unit) When two or more outdoor units are installed in a location, they must be positioned such that one unit will not be taking the hot discharge air from another. This also applies when two or more units are installed one above the other.
  • Page 95: Vacuuming And Charging

    B) For MMC – C/CR series Model MMC 075C/CR MMC 100C MMC 150C A (mm) 1,200 1,200 1,200 B (mm) C (mm) MMC 075C/CR / 100C MMC 150C Vacuuming And Charging Vacuuming is necessary to eliminate all moisture and air from the system. The Series II Condensing Unit is provided with flare valve fittings and charging nipples.
  • Page 96 System Refrigerant Charge Level Guidelines COOLING ONLY Refrigerant Charge Indoor Outdoor Liquid Pipe Gas Pipe (kg/7.5m pipe length) MDB075B MMC075B 1/2" 1" 2500 4.00 MDB075B MMC075C 1/2" 1" 2500 4.50 MDB100B MMC100B 5/8" 1-1/8" 3200 7.60 MDB100B MMC100C 5/8" 1-1/8"...
  • Page 97 HEATPUMP Refrigerant Charge Indoor Outdoor Liquid Pipe Gas Pipe (kg/7.5m pipe length) MDB075BR MMC075CR 1/2" 1" 2500 MDB100BR MMC100BR 5/8" 1-1/8" 3200 MDB125CR MMC125BR 5/8" 1-1/4" 4200 MDB150BR2 MMC075CR x 2 1/2" 1" 4600 4.6 x 2 MDB200BR2 MMC100BR x 2 5/8"...
  • Page 98: Servicing And Maintenance

    Servicing And Maintenance The design concept of the Condensing Unit is such that all servicing can be done from the front and side of the unit. Upon removal of front and side panel, all the electrical "terminal box", fan and motor assembly and compressor are easily accessible.
  • Page 99: Operation

    Operation Electrical Connection Wiring regulations about wire diameter differs from country to country. Please refer to your LOCAL ELECTRICAL CODES for field wiring rules. Be sure that installation comply with such rules and regulations. General Precaution Ensure that the rated voltage of the unit correspond to the name plate before carrying out proper wiring according to the wiring diagram.
  • Page 100 3. Auto Mode Selection SW5(dip 5) a. Auto mode off b. Auto mode on Note : Factory preset : SW5 = off ~ auto mode off 4. Stage Differential Temperature Differential temperature is the temperature difference between turning on or off 1 compressor to another compressor in thermostat cycle.
  • Page 102: Troubleshooting

    8. Sequential Control For Cool Mode The starting sequence for indoor fan, outdoor fan and compressors is shown as below: 2 seconds Start Indoor fan 15 seconds 2 seconds outdoor fan 1 compressor 1* 15 seconds 2 seconds outdoor fan 2 compressor 2* 15 seconds 2 seconds...
  • Page 103 The following charts are efficient checking procedures for troubleshooting when these fan-coil units are combined with condensing units with the unit standard wiring. For dual circuited models, perform the procedures for each. No Cooling : Faulty : Check : Cause Remedy No Cooling ( Compresor Does Not Start ) Stop...
  • Page 104: Insufficient Cooling

    Insufficient Cooling Insufficient Cooling Cycling On Compressor Cycling High Discharge Pressure or Low See "High Discharge Pressure" or Tripping Suction Pressure "Low Suction Pressure" Dual Pressure Switch Clogged Capillary or Pressure Repair Clogging and Replace Switch The Switch If Required Switch Faulty Repair or Change If Necessary Running...
  • Page 105: Low Suction Pressure

    High Suction Pressure High Suction Pressure Evaporator Air Inlet Excessive Fresh Air Intake Reduce The Fresh Air Intake Temperature Insufficient Duct Insulation Reinforce The Duct Insulation Defective Compressor Valve Change Or Repair The Compressor Overcharged Refrigerant Purge The Refrigerant Low Suction Pressure Low Suction Pressure Evaporator Restricted...
  • Page 106: Part List

    Part List COOLING MODEL (INDOOR) HORIZONTAL AIR DISCHARGE MODEL : MDB 075B NOTE : 1) WITH CONTACTOR 2) WITH TORIN FORWARD CURVE BLOWER 3) WITH ALCO THERMOSTATIC EXPANSION VALVE 4) WITH PE INSULATION 5) FOR 220-240V/1PH/50Hz 6) FOR LOCAL AND EXPORT SPEC.
  • Page 107 MODEL : MDB 100B NOTE : 1) WITH CONTACTOR 2) WITH TORIN FORWARD CURVE BLOWER 3) WITH ALCO THERMOSTATIC EXPANSION VALVE 4) WITH PE INSULATION 5) FOR 220-240V/1PH/50Hz 6) FOR LOCAL AND EXPORT SPEC. NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., BASE PAN ASSY., FRONT PANEL SCREW, TRUSS HEAD PHILIP...
  • Page 108 MODEL : MDB125B NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH ALCO THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR HORIZONTAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN...
  • Page 109 MODEL : MDB125C NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH DANFOSS THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR HORIZONTAL AIR DISCHARGE ONLY NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., BASE PAN ASSY., SIDE PANEL LEFT...
  • Page 110 MODEL : MDB150B1 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH ALCO THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR HORIZONTAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN...
  • Page 111 MODEL : MDB150C1 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH DANFOSS THERMOSTATIC EXPANSION VALVE 4) WITH PE INSULATION 5) FOR 400V/3PH/50Hz 6) FOR LOCAL AND EXPORT SPEC. 7) FOR HORIZONTAL AIR DISCHARGE ONLY NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION...
  • Page 112 MODEL : MDB150B2 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH ALCO THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR HORIZONTAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN...
  • Page 113 MODEL : MDB200B2 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH ALCO THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR HORIZONTAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN...
  • Page 114 MODEL : MDB250B2 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH ALCO THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR HORIZONTAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., BASE PAN ASSY., SIDE PANEL LEFT...
  • Page 115 MODEL : MDB300B3 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH ALCO THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR HORIZONTAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., BASE PAN ASSY., SIDE PANEL LEFT...
  • Page 116 MODEL : MDB350B3 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH ALCO THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR HORIZONTAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., BASE PAN ASSY., SIDE PANEL LEFT...
  • Page 117 MODEL : MDB 400B4 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH ALCO THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR HORIZONTAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN...
  • Page 118 MODEL : MDB450B3 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH DANFOSS THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR HORIZONTAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN...
  • Page 119 MODEL : MDB500B4 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH ALCO THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR HORIZONTAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN...
  • Page 120 MODEL : MDB600B4 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH DANFOSS THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR HORIZONTAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., SIDE PANEL BACK ASSY., BASE PAN...
  • Page 121 MODEL : MDB750B5 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH DANFOSS THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR HORIZONTAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., SIDE PANEL BACK ASSY., BASE PAN...
  • Page 122 VERTICAL AIR DISCHARGE MODEL : MDB125B NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH ALCO THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR VERTICAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER...
  • Page 123 MODEL :MDB150B1 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH ALCO THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR VERTICAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN SCREW, TRUSS HEAD PHILIP...
  • Page 124 MODEL : MDB150B2 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH ALCO THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR VERTICAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN...
  • Page 125 MODEL : MDB200B2 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH ALCO THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR VERTICAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN...
  • Page 126 MODEL : MDB250B2 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH ALCO THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR VERTICAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., BASE PAN ASSY., SIDE PANEL LEFT...
  • Page 127 MODEL : MDB300B3 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH ALCO THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR VERTICAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., BASE PAN ASSY., SIDE PANEL LEFT...
  • Page 128 MODEL : MDB350B3 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH ALCO THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR VERTICAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., BASE PAN ASSY., SIDE PANEL LEFT...
  • Page 129 MODEL : MDB400B4 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH ALCO THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR VERTICAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN...
  • Page 130 MODEL : MDB450B3 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH DANFOSS THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR VERTICAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN...
  • Page 131 MODEL : MDB500B4 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH ALCO THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR VERTICAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN...
  • Page 132 MODEL : MDB600B4 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH DANFOSS THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR VERTICAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., SIDE PANEL BACK ASSY., BASE PAN...
  • Page 133 MODEL : MDB750B5 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH DANFOSS THERMOSTATIC EXPANSION VALVE 4) FOR 400V/3PH/50Hz 5) FOR LOCAL AND EXPORT SPEC. 6) FOR VERTICAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., SIDE PANEL BACK ASSY., BASE PAN...
  • Page 134 HEATPUMP MODEL (INDOOR) HORIZONTAL AIR DISCHARGE MODEL : MDB075BR NOTE : 1) FOR 220-240V/1PH/50Hz NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., BASE PAN 12 ASSY., BLOWER FLANGE 23 WASHER, PLAIN PANEL, BASE COVER 13 ASSY., BLOWER HOUSING 24 BOLT, HEXAGON ASSY., DRAIN PAN 14 ASSY., TOP PANEL 25 WASHER, PLAIN...
  • Page 135 MODEL : MDB100BR NOTE : 1) FOR 220-240V/1PH/50Hz NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., BASE PAN 12 ASSY., BLOWER FLANGE 23 WASHER, PLAIN PANEL, BASE COVER 13 ASSY., BLOWER HOUSING 24 BOLT, HEXAGON ASSY., DRAIN PAN 14 ASSY., TOP PANEL 25 WASHER, PLAIN ASSY., DRAIN PAN SMALL 15 ASSY., FILTER SECTION...
  • Page 136 MODEL : MDB125CR NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) WITH DANFOSS THERMOSTATIC EXPANSION VALVE 4) WITH PE INSULATION 5) FOR 400V/3PH/50Hz 6) FOR EXPORT SPEC. 7) FOR HORIZONTAL AIR DISCHARGE ONLY NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., BASE PAN...
  • Page 137 MODEL : MDB150BR2 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) FOR 400V/3PH/50Hz 4) FOR HORIZONTAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN SCREW, TRUSS HEAD PHILIP RIGHT ASSY., SIDE PANEL SMALL ASSY., BLOWER HOUSING...
  • Page 138 MODEL : MDB200BR2 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) FOR 400V/3PH/50Hz 4) FOR HORIZONTAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN SCREW, TRUSS HEAD PHILIP LEFT ASSY., SIDE PANEL SMALL ASSY., BLOWER HOUSING...
  • Page 139 MODEL : MDB250BR2 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) FOR 400V/3PH/50Hz 4) FOR HORIZONTAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN SCREW, WOOD RIGHT ASSY., SIDE PANEL SMALL ASSY., BLOWER HOUSING BOLT, HEXAGON...
  • Page 140 MODEL : MDB300BR3 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) FOR 400V/3PH/50Hz 4) FOR HORIZONTAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN SCREW, WOOD RIGHT ASSY., SIDE PANEL SMALL ASSY., BLOWER HOUSING BOLT, HEXAGON...
  • Page 141 MODEL : MDB350BR3 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) FOR 400V/3PH/50Hz 4) FOR HORIZONTAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN SCREW, WOOD RIGHT ASSY., SIDE PANEL SMALL ASSY., BLOWER HOUSING BOLT, HEXAGON...
  • Page 142 MODEL : MDB400BR4 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) FOR 400V/3PH/50Hz 4) FOR HORIZONTAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., SIDE PANEL BACK ASSY., BASE PAN WASHER, SPRING RIGHT ASSY., SIDE PANEL FRONT ASSY., BLOWER HOUSING NUT, HEXAGON...
  • Page 143 MODEL : MDB500BR4 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) FOR 400V/3PH/50Hz 4) FOR HORIZONTAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., SIDE PANEL BACK ASSY., BASE PAN WASHER, SPRING RIGHT ASSY., SIDE PANEL FRONT ASSY., BLOWER HOUSING NUT, HEXAGON...
  • Page 144 VERTICAL AIR DISCHARGE MODEL : MDB150BR2 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) FOR 400V/3PH/50Hz 4) FOR VERTICAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN SCREW, TRUSS HEAD PHILIP RIGHT ASSY., SIDE PANEL SMALL...
  • Page 145 MODEL : MDB200BR2 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) FOR 400V/3PH/50Hz 4) FOR VERTICAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN SCREW, TRUSS HEAD PHILIP LEFT ASSY., SIDE PANEL SMALL ASSY., BLOWER HOUSING...
  • Page 146 MODEL : MDB250BR2 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) FOR 400V/3PH/50Hz 4) FOR VERTICAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN SCREW, WOOD RIGHT ASSY., SIDE PANEL SMALL ASSY., BLOWER HOUSING BOLT, HEXAGON...
  • Page 147 MODEL : MDB300BR3 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) FOR 400V/3PH/50Hz 4) FOR VERTICAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN SCREW, WOOD RIGHT ASSY., SIDE PANEL SMALL ASSY., BLOWER HOUSING BOLT, HEXAGON...
  • Page 148 MODEL : MDB350BR3 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) FOR 400V/3PH/50Hz 4) FOR VERTICAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., COIL SIDE COVER ASSY., BASE PAN SCREW, WOOD RIGHT ASSY., SIDE PANEL SMALL ASSY., BLOWER HOUSING BOLT, HEXAGON...
  • Page 149 MODEL : MDB400BR4 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) FOR 400V/3PH/50Hz 4) FOR VERTICAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., SIDE PANEL BACK ASSY., BASE PAN WASHER, SPRING RIGHT ASSY., SIDE PANEL FRONT ASSY., BLOWER HOUSING NUT, HEXAGON...
  • Page 150 MODEL : MDB500BR4 NOTE : 1) WITH TECO INDUCTION MOTOR 2) WITH NICOTRA FORWARD CURVE BLOWER 3) FOR 400V/3PH/50Hz 4) FOR VERTICAL AIR DISCHARGE NO DESCRIPTION NO DESCRIPTION NO DESCRIPTION ASSY., SIDE PANEL BACK ASSY., BASE PAN WASHER, SPRING RIGHT ASSY., SIDE PANEL FRONT ASSY., BLOWER HOUSING NUT, HEXAGON...
  • Page 151 COOLING MODEL (OUTDOOR) HORIZONTAL AIR DISCHARGE MODEL : MMC075B NOTE : 1) WITH COPELAND SCROLL COMPRESSOR 2) WITH TECO FAN MOTOR 3) WITH NANTONG AUTO RESET H/L PRESSURE SWITCH 4) WITH TORIN FAN BLADE 5) FOR 380-420V/3PH/50Hz 6) FOR HORIZONTAL AIR DISCHARGE 7) FOR EXPORT SPEC DESCRIPTION DESCRIPTION...
  • Page 152 MODEL : MMC100B NOTE : 1) WITH COPELAND SCROLL COMPRESSOR 2) WITH TECO FAN MOTOR 3) WITH NANTONG AUTO RESET H/L PRESSURE SWITCH 4) WITH TORIN FAN BLADE 5) FOR 380-420V/3PH/50Hz 6) FOR HORIZONTAL AIR DISCHARGE 7) FOR EXPORT SPEC DESCRIPTION DESCRIPTION DESCRIPTION...
  • Page 153 MODEL : MMC125B NOTE : 1) WITH COPELAND SCROLL COMPRESSOR 2) WITH TECO FAN MOTOR 3) WITH NANTONG AUTO RESET H/L PRESSURE SWITCH 4) WITH TORIN FAN BLADE 5) FOR 380-420V/3PH/50Hz 6) FOR HORIZONTAL AIR DISCHARGE 7) FOR EXPORT SPEC DESCRIPTION DESCRIPTION DESCRIPTION...
  • Page 154 MODEL : MMC 075C NOTE : 1) WITH COPELAND SCROLL COMPRESSOR 2) WITH HEADLINE FAN MOTOR 3) WITH AUTO RESET H/L PRESSURE SWITCH 4) WITH TORIN FAN BLADE 5) FOR 380-420V/3PH/50Hz 6) FOR EXPORT SPEC DESCRIPTION DESCRIPTION DESCRIPTION ASSY., BASE PAN PLATE, ORIFICE SUPPORT SCREW, SELF TAPPING ASSY., COIL...
  • Page 155 MODEL : MMC 100C NOTE : 1) WITH COPELAND SCROLL COMPRESSOR 2) WITH HEADLINE FAN MOTOR 3) WITH AUTO RESET H/L PRESSURE SWITCH 4) WITH TORIN FAN BLADE 5) FOR 380-420V/3PH/50Hz 6) FOR EXPORT SPEC DESCRIPTION DESCRIPTION DESCRIPTION ASSY., BASE PAN STRUCTURE, ORIFICE SUPPORT SCREW, WOOD ASSY., COIL...
  • Page 156 VERTICAL AIR DISCHARGE MODEL : MMC075B NOTE : 1) WITH COPELAND SCROLL COMPRESSOR 2) WITH TECO FAN MOTOR 3) WITH NANTONG AUTO RESET H/L PRESSURE SWITCH 4) WITH TORIN FAN BLADE 5) FOR 380-420V/3PH/50Hz 6) FOR VERTICAL AIR DISCHARGE 7) FOR EXPORT SPEC DESCRIPTION DESCRIPTION DESCRIPTION...
  • Page 157 MODEL : MMC100B NOTE : 1) WITH COPELAND SCROLL COMPRESSOR 2) WITH TECO FAN MOTOR 3) WITH NANTONG AUTO RESET H/L PRESSURE SWITCH 4) WITH TORIN FAN BLADE 5) FOR 380-420V/3PH/50Hz 6) FOR VERTICAL AIR DISCHARGE 7) FOR EXPORT SPEC DESCRIPTION DESCRIPTION DESCRIPTION...
  • Page 158 MODEL : MMC125B NOTE : 1) WITH COPELAND SCROLL COMPRESSOR 2) WITH TECO FAN MOTOR 3) WITH NANTONG AUTO RESET H/L PRESSURE SWITCH 4) WITH TORIN FAN BLADE 5) FOR 380-420V/3PH/50Hz 6) FOR VERTICAL AIR DISCHARGE 7) FOR EXPORT SPEC DESCRIPTION DESCRIPTION DESCRIPTION...
  • Page 159 MODEL : MMC150C NOTE : 1) WITH COPELAND SCROLL COMPRESSOR 2) WITH HEADLINE FAN MOTOR 3) WITH NANTONG AUTO RESET H/L PRESSURE SWITCH 4) WITH TORIN FAN BLADE 5) FOR 380-420V/3PH/50Hz 6) FOR EXPORT SPEC DESCRIPTION DESCRIPTION DESCRIPTION ASSY., STRUCTURE FRONT ASSY., BASE PAN SCREW, WOOD RIGHT...
  • Page 160 HEATPUMP MODEL HORIZONTAL AIR DISCHARGE MODEL : MMC075CR NOTE : 1) WITH COPELAND SCROLL COMPRESSOR 2) WITH HEADLINE FAN MOTOR 3) FOR 380-420V/3PH/50Hz 4) FOR EXPORT SPEC DESCRIPTION DESCRIPTION DESCRIPTION CLAMP, SUCTION TUBE BRACKET, FAN MOTOR 26” WASHER, PLAIN CLAMP, LIQUID TUBE FAN BLADE (TORIN) PLATE, ORIFICE SUPPORT STRUCTURE, BACK RIGHT...
  • Page 161 VERTICAL AIR DISCHARGE MODEL : MMC100BR NOTE : 1) WITH COPELAND SCROLL COMPRESSOR 2) WITH HEADLINE FAN MOTOR 3) FOR VERTICAL AIR DISCHARGE 4) FOR 380-420V/3PH/50Hz 5) FOR EXPORT SPEC DESCRIPTION DESCRIPTION DESCRIPTION GUARD, FAN ASSY., BASE PAN HOISTING BRACKET ASSY., STRUCTURE FRONT FAN BLADE ASSY., COIL LEFT...
  • Page 162 MODEL : MMC125BR NOTE : 1) WITH COPELAND SCROLL COMPRESSOR 2) WITH HEADLINE FAN MOTOR 3) FOR VERTICAL AIR DISCHARGE 4) FOR 380-420V/3PH/50Hz 5) FOR EXPORT SPEC DESCRIPTION DESCRIPTION DESCRIPTION ASSY., STRUCTURE FRONT FAN GUARD (TORIN) HOISTING BRACKET RIGHT WELD NUT FAN BLADE, 30”...
  • Page 163 REGISTERED ISO 9002 ©2004 McQuay International +1 (800) 432-1342 www.mcquay.com...