Low oil alarm system
The low oil alarm system is designed to prevent engine damage caused by an insufficient amount
of oil in the crankcase. Before the oil level in the crankcase falls below a safe limit, the low oil
alarm system will automatically shut down the engine (the engine switch will remain in the ON
position).
If the low oil alarm system shuts down the engine, the low oil alarm indicator light (red) will come
on when you operate the starter and the engine will not run. If this occurs add engine oil.
Air Conditioning Operation
When running in parallel two IG2000P models can start and run most 13,500 BTU Air conditioners.
For best results, the SMART throttle switches should be in the off position. Bring the generators to
normal operating temperatures before applying the air conditioning load. Always allow a 2 minute
wait period when manually cycling an air conditioner off and on. A longer wait period may be
required under unusually hot weather conditions. Additionally, all other loads should be turned off
until the air conditioner has started and is performing normally. It is also important to follow the air
conditioner manufacturer's instructions for starting and restarting for proper operation. Some air
conditioner manufacturers offer a start capacitor or rapid start kit as an extra cost option. The lack
of a start capacitor can cause the air conditioner to draw too high a starting current and overload
the generator. Contact your air conditioner dealer if you consistently have problems starting your
air conditioner with the generator.