DC application
The DC receptacle may be used for charging 12 volt automotive-type batteries only, the
no load voltage is 15V-30V.
■ In DC operation, turn the Smart-throttle switch to the OFF position.
1. Connect the charging cables to the DC receptacle of the generator and then to the battery
terminals.
■ To prevent the possibility of creating a spark near the battery, connect the charging cable first
to the generator then to the battery. Disconnect the cable first at the battery.
■ Before connecting charging cables to a battery that is installed in a vehicle, disconnect the
vehicle's ground battery cable. Reconnect the vehicle's ground battery cable after the
charging cables are removed. This procedure will prevent the possibility of a short circuit and
sparks if you make accidental contact between a battery terminal and the vehicle's frame or
body.
■ Do not attempt to start an automobile engine with the generator still connected to the battery.
The generator may be damaged.
■ Connect the positive battery terminal to the positive charging cord. Do not reverse the
charging cables, or serious damage to the generator and/or battery may occur.