The DC Converter module has three status LED's. These LED's indicate battery
status, AC mains status, and lastly the temperature of the converter. The LED's
operate in the following manner:
LED
Battery
status
AC Mains
Converter
temperature
The converter module has a current limiting fuse on the high-voltage supply. Caution
must be exercised when checking this fuse. The procedure to replace the fuse is
outlined below:
1. Disconnect the mains from the entire system. This includes the A10, and
the converter module.
2. Disconnect the battery.
3. Disconnect the 6-way header that connects the converter module to the A10.
The converter module is now off, and the board is safe to handle.
4. Remove the fuse protection housing (If the housing is still in place).
5. Remove the fuse and replace it with a 5A, 250V, fast-blow fuse. (Dimensions
5x20mm).
6. Reconnect the 6-way header.
7. Reconnect the battery.
8. Reconnect the mains.
Upon reconnecting, if the converter module fails to function correctly in the event of a
power failure, refer to an installer or service technician.
18 - Centurion Sliding Gate Operators User Guide
When ON,
it indicates:
Battery is
fully charged
Mains
present
DC converter will
shut down until it
has cooled to
Overheated
normal operating
temperature range.
When OFF,
Logic
it indicates:
Voltage
Mains
failure
Converter
temperature
normal
Logic
DC converter will
shut down until
battery reaches
low
normal operating
voltage.
DC converter will
power A10 until
mains restored or
battery voltage <
threshold