Page: 40
Service Guide ML320/321Turbo
Chapter 3 Parts Replacement

3.3.16 Transformer Assy

(see 3.3.4
).
(1) Remove the upper cover
(2) Remove AC inlet 1 and AC switch 2 from the frame guide.
(3) Disconnect the cable 3 from the connector 4 on the Control/Power Supply Board 5.
(4) Remove a screw 6 and disconnect ground cable 7.
(5) Remove two screws 8 and shift the transformer Assy 9 to the left and remove it.
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)