APRILIA ATLANTIC 125 Workshop Manual page 213

Hide thumbs Also See for ATLANTIC 125:
Table of Contents

Advertisement

ATLANTIC 125 - 200
Thermal switch test
Remove the air dam,
Disconnect the two connectors.
Release and remove the thermal switch (2).
Set a multimeter (3) to the Ohm range to the thermal
switch (2) as shown in the figure.
Suspend the thermal switch (2) in a container filled with
coolant (4).
Suspend a thermometer (5) with a 0-150°C (32 -302°F)
range in the container.
Place the container on a gas burner (6) and heat up
the coolant gradually.
Check the temperature reading of the thermometer (4)
and the resistance reading indicated by the multimeter.
The switch operating threshold is between 90 and
100°C (194 - 212°F). When this threshold is exceeded,
tester reading should change from ∞ to 0 ohm.
REAR TOP BOX LIGHT SWITCH TEST
Raise the saddle and check continuity across the two
terminals with a multimeter set to the Ohm range.
Correct reading when switch is released (saddle raised) :
0 ohm
Correct reading with switch pressed (saddle closed): ∞
ohm