The user also has the option of transferring firmware and configuration files to and from the internal Flash drive, located on the
Switch. Using this window, the user can receive a configuration or firmware file from a TFTP server, or transfer that firmware or
configuration file to a TFTP server. More about configuring the internal Flash drive can be found in the next section entitled Flash
File Services.
TFTP server software is a part of many network management software packages – such as NetSight, or can be obtained as a
separate program. To update the Switch's firmware or configuration file, open the TFTP Services hyperlink, located in the
Administration folder.
The following parameters can be configured:
Parameter
Description
Operation
Select a service for the TFTP server to perform from the drop down window:
Server IPv4
Enter the IPv4 address of the server from which to upload or download firmware and
Address
configuration.
Server IPv6
Enter the IPv6 address of the server from which to upload or download firmware and
configuration.
Address
Local File Name
Enter the path and filename of the firmware or configuration file to upload or download, located
on the TFTP server.
Image File in Flash
To select a firmware file from the internal Flash drive to be transferred, or to load a firmware file
on to the Flash drive, enter the path and filename here and click the corresponding check box.
Remember, the only path that can be used on the flash is named C:/. (ex. c:/runtime.had)
Configuration File
To select a configuration file from the internal Flash drive to be transferred, or to load a
in Flash
configuration file on to the Flash drive, enter the path and filename here and click the
corresponding check box. Remember, the only path that can be used on the flash is named
C:/. (ex. c:/configuration.had)
Click Start to initiate the file transfer.
xStack DGS-3600 Series Layer 3 Gigabit Ethernet Managed Switch
Download Firmware - Enter the IP address of the TFTP server and specify the
location of the new firmware on the TFTP server. Click Start to record the IP
address of the TFTP server and to initiate the file transfer.
Download Configuration - Enter the IP address of the TFTP server, and the path
and filename for the Configuration file on the TFTP server. Click Start to record the
IP address of the TFTP server and to initiate the file transfer.
Upload Configuration - Enter the IP address of the TFTP server and the path and
filename for the switch settings on the TFTP server. Click Start to record the IP
address of the TFTP server and to initiate the file transfer.
Upload Log - Enter the IP address of the TFTP server and the path and filename
for the history log on the TFTP server. Click Start to record the IP address of the
TFTP server and to initiate the file transfer.
Upload Attack Log - Enter the IP address of the TFTP server and the path and
filename for the attack log on the TFTP server. Click Start to record the IP address
of the TFTP server and to initiate the file transfer.
Upload Firmware - Enter the IP address of the TFTP server and the path and
filename for the place to put this firmware on the TFTP server. Click Start to record
the IP address of the TFTP server and to initiate the file transfer.
49