OPERATING HEATER

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING:
If you do not follow these instructions exactly, a fire or explosion may result causing property
damage, personal injury or loss of life.
NOTICE:
During initial operation of the new
Orange flame will also be present. Open a window to vent smell. This will only last a few hours.
CAUTION:
Do not try to adjust heating levels by using the equipment shutoff valve.
A.
This appliance has a pilot which must be lighted by the electronic ignitor. When lighting the pilot, follow
these instructions exactly.
B.
BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
·
Do not try to light any appliance.
·
Do not touch any electrical switch; do not use any phone in your building.
·
Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
·
If you cannot reach your gas supplier, call the fire department
C. Use only your hand to push in control knob. Never use tools. If the appliance could not operate, do not try
to repair it, Call a qualified service technician or gas supplier. Forced or attempted, re-pair may result in a
fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of the control system and any gas control which has been
under water.
Note:
Please wait one minute after shutting off fireplace to allow the electronic module to reset before starting
again.
THERMOSTATIC CONTROL OPERATION
Note: The thermostat sensing bulb measures the temperature (depending on housing construction, the
thermostatic control used on this model differs from standard thermostats. The thermostatic control used on
this model differs from standard thermostats. Standard thermostats simply turn the burner on and off. The
thermostat used on this heater senses the room temperature. At times the room may exceed the set
temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below
the set temperature. The control knob can be set to any comfort level between HIGH (5) and LOW (1).
fireplace
, burning logs will give off a paper-burning smell.