Travis Industries 564 Installation Manual page 57

Built-in direct vent fireplace
Hide thumbs Also See for 564:
Table of Contents

Advertisement

Finalizing the Installation
4
Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice
Lift the pilot hood
a
off the pilot
assembly.
5
Replace the firebox
components. Install
the logs and embers.
Replace the glass.
6
Remove the regulator
from the front of the gas
control valve. Replace
with the propane
regulator, using the new
gasket and screws
included with the
regulator. NOTE: Leak
test this area after
the heater is
installed, gas is
connected, and the
main burner is lit.
© Travis Industries
Remove the orifice and replace with the LP orifice. Screw the
c
orifice all the way in and replace the pilot hood.
Use a hex wrench to
b
unscrew the orifice.
5/32" Hex
NOTE: when re-attaching,
this pin lines up with the
notch in the pilot hood.
a
Remove and discard the three
screws using a slotted screwdriver
of Torx T-20.
Slotted
Screwdriver
(or T-20 Torx)
c
Install the LP regulator. Use
the screws included with the
LP regulator. Tighten to
approximately 25 Lbs. torque.
Slotted
Screwdriver
(or T-20 Torx)
4 0 7 0 6 2 0
(for qualified installers only)
Orifice Identification:
35
Remove and discard the
regulator, diaphram, spring
and center post.
NOTE: Make sure the
regulator gasket is correctly
aligned before installation.
5 7
LP (Propane) Orifice
35
NG (Natural Gas) Orifice
62
b
d
Place the LP
label on the base
of the fireplace
near the gas
control valve.
100-01188_000

Advertisement

Table of Contents
loading

This manual is also suitable for:

564 space saver

Table of Contents