Upon selecting any one of the 3 options (zone a, b and c) you may enter a zone number and then select "disable", "turn on", "turn
off", "pulse active" or "toggle".

4.9 DEFINE CUSTOM

This mode allows you to define up to 5 zones names (in addition to the zone names that can be defined in the DEFINE ZONES
mode - see par. 4.3).
(see figure 4.1a)
9. DEFINE CUSTOM
I
OK
CUST. ZONES NAME
<OK> TO EXIT

4.10 DIAGNOSTIC TEST

This mode allows you to test the function of all protected
area wireless sensors / wireless sirens / wireless keypads /
GPRS / LAN connection / options for resetting the
Broadband Module and to receive / review information
regarding the received signal strength.
The diagnostic test process is shown in figure 4.10.
For WL Sensors / WL Sirens / WL Keypads:
Three reception levels are sensed and reported.
Received Signal Strength Indication:
Reception
Buzzer Response
Strong
Happy Tune twice ( - - - –––– ) ( - - - ––––)
Good
Happy Tune ( - - - –––– )
Poor
Sad tune ( –––––––– )
24
PGM: BY ARM AWAY
disable
turn on
turn off
pulse active
PGM: BY DELAY
disable
turn on
turn off
pulse active
EDIT USER TERM 1
EDIT USER TERM 2
I
OK
To edit User Terms, use the following buttons on the control panel keypad:
press
press
Figure 4.9 – Define Custom
DEFINE PGM
PGM: PULSE TIME
pulse time 2s
pulse time 30s
pulse time 2m
pulse time 4m
PGM: BY ARM HOME
disable
turn on
turn off
pulse active
PGM: BY KEYFOB
disable
(**)
turn on
turn off
pulse active
toggle
Figure 4.8 Define PGM
EDIT USER TERM 3
to scroll backward; press
to change from small caps to big caps ; press
IMPORTANT! Reliable reception must be assured. Therefore,
a "poor" signal strength is not acceptable. If you get a
"poor" signal from a certain detector, re-locate it and re-test
until a "good" or "strong" signal strength is received. This
principle should be followed during the initial testing and also
throughout subsequent system maintenance.
Select "start"/"stop"and
enter the desired time.
PGM: BY DISARM
disable
turn on
turn off
pulse active
PGM: BY ZONES
a - zone
c - zone
b - zone
(SELECT BY
OR
)
x - zone
Z: _ _
applicable for PGM only - not for X-10.
(ENTER ZONE NUMBERS)
disable
turn on
turn off
pulse active
toggle
EDIT USER TERM 4
to scroll forward ;
for space
PGM GENERAL DEF
LOCKOUT TIME
start - HH:MM A
stop - HH:MM A
TIME - 00:00 A
PGM: BY MEMORY
disable
turn on
turn off
pulse active
PGM: BY LINE FAIL
by line fail no
by line fail yes
Note:PGM BY LINE FAIL function is