4. Capacity Range

Combination ratio
Connection capacity: 50% - 130%
Total capacity index of the indoor units
Combination ratio =
Min.
Type
combination
ratio
Single outdoor units
Double outdoor units
50%
Triple outdoor units
Note: * When outdoor-air processing units (FXMQ-MF) and standard indoor units are connected, the total connection
capacity of the outdoor-air processing units (FXMQ-MF) must not exceed 30% of the capacity index of the
outdoor units.
Outdoor unit combinations
Capacity
HP
Model name
index
8 HP
200
RQYQ8PY1B
10 HP
250
RQYQ10PY1B
12 HP
300
RQYQ12PY1B
14 HP
350
RQYQ14PY1B
16 HP
400
RQYQ16PY1B
18 HP
450
RQYQ18PY1B
20 HP
500
RQYQ20PY1B
22 HP
550
RQYQ22PY1B
24 HP
600
RQYQ24PY1B
26 HP
650
RQYQ26PY1B
28 HP
700
RQYQ28PY1B
30 HP
750
RQYQ30PY1B
32 HP
800
RQYQ32PY1B
34 HP
850
RQYQ34PY1B RQYQ10PY1B + RQYQ10PY1B + RQYQ14PY1B
36 HP
900
RQYQ36PY1B RQYQ10PY1B + RQYQ10PY1B + RQYQ16PY1B
38 HP
950
RQYQ38PY1B RQYQ10PY1B + RQYQ12PY1B + RQYQ16PY1B
40 HP
1,000
RQYQ40PY1B RQYQ12PY1B + RQYQ12PY1B + RQYQ16PY1B
42 HP
1,050
RQYQ42PY1B RQYQ10PY1B + RQYQ16PY1B + RQYQ16PY1B
44 HP
1,100
RQYQ44PY1B RQYQ12PY1B + RQYQ16PY1B + RQYQ16PY1B
46 HP
1,150
RQYQ46PY1B RQYQ14PY1B + RQYQ16PY1B + RQYQ16PY1B
48 HP
1,200
RQYQ48PY1B RQYQ16PY1B + RQYQ16PY1B + RQYQ16PY1B
*1. For multiple connections of 18 HP systems and above, the outdoor unit multi connection piping kit (separately sold)
is required.
*2. Total capacity index of connectable indoor units must be 50%–130% of the capacity index of the outdoor units.
*3. When outdoor-air processing units (FXMQ-MF) and standard indoor units are connected, the total connection
capacity of the outdoor-air processing units (FXMQ-MF) must not exceed 30% of the capacity index of the outdoor
units.
General Information
Capacity index of the outdoor units
Types of connected indoor units
Standard indoor units
130%
Combination
RQYQ8PY1B
RQYQ10PY1B
RQYQ12PY1B
RQYQ14PY1B
RQYQ16PY1B
RQYQ8PY1B + RQYQ10PY1B
RQYQ8PY1B + RQYQ12PY1B
RQYQ10PY1B + RQYQ12PY1B
RQYQ12PY1B + RQYQ12PY1B
RQYQ10PY1B + RQYQ16PY1B
RQYQ12PY1B + RQYQ16PY1B
RQYQ14PY1B + RQYQ16PY1B
RQYQ16PY1B + RQYQ16PY1B
Max. combination ratio
Type of connected Air Treatment Equipments
VKM
When VKM
When VKM is
and indoor
only
units are
connected
connected
130%
130%
Total capacity index of
connectable indoor units
Outdoor unit multi
*1
connection piping kit
Combination (%)
50%
100
125
150
175
200
225
250
275
300
BHFP22P100
325
350
375
400
425
450
475
500
BHFP22P151
525
550
575
600

Capacity Range

FXMQ-MF
When
When
FXMQ-MF
FXMQ-MF is
and indoor
only
units are
connected
connected
100%
100%*
Maximum
*2 *3
number of
connectable
indoor units
100%
130%
200
260
13
250
325
16
300
390
19
350
455
22
400
520
26
450
585
29
500
650
32
550
715
35
600
780
39
650
845
42
700
910
45
750
975
48
800
1,040
52
850
1,105
55
900
1,170
58
950
1,235
61
1,000
1,300
1,050
1,365
1,100
1,430
64
1,150
1,495
1,200
1,560
7