Installation distance in case of non­combustible wall 
We recommend a minimum distance to non­combustible material of 50 mm (F) for 
clean­ing considerations. 
Using uninsulated flue pipe, the minimum distance to a combustible wall must be 
450mm or 225mm if the wall is heatshielded ( see Section J of the Building 
Regulations ) from the flue pipe. 
For the Installer 
Finally before firing the stove for the first time a check should be made to ensure 
that the  assembly and stove installation has been satisfactory and that there are 
no leaks in any seals in the appliance and appliance connections to the chimney. 
Ensure that the appliance and chimney flue are functioning correctly before finally 
handing over to the user. If necessary read the later parts of this manual for 
guidance on care required when first lighting. 
Inform the user that the appliance has been commissioned and ready to use and 
give instruction on the safe operation of the stove. 
These Instructions must be left with the user and the user should be instructed to 
keep them in a safe place.