Installation distance in case of noncombustible wall
We recommend a minimum distance to noncombustible material of 50 mm (F) for
cleaning considerations.
Using uninsulated flue pipe, the minimum distance to a combustible wall must be
450mm or 225mm if the wall is heatshielded ( see Section J of the Building
Regulations ) from the flue pipe.
For the Installer
Finally before firing the stove for the first time a check should be made to ensure
that the assembly and stove installation has been satisfactory and that there are
no leaks in any seals in the appliance and appliance connections to the chimney.
Ensure that the appliance and chimney flue are functioning correctly before finally
handing over to the user. If necessary read the later parts of this manual for
guidance on care required when first lighting.
Inform the user that the appliance has been commissioned and ready to use and
give instruction on the safe operation of the stove.
These Instructions must be left with the user and the user should be instructed to
keep them in a safe place.
21