RAIS ­ manual for Rais Rina & Rais Viva 
A single wall metal fluepipe is suitable for connecting the stove to the chimney but is not 
suitable for using for the complete chimney. The chimney and connecting fluepipe must 
have a minimum diameter of 150 mm and its dimension should be not less than the size of 
the outlet socket of the stove. 
Any bend in the chimney or connecting fluepipe should not exceed 45°.  90° bends should 
not be used. 
Combustible material should not be located where the heat dissipating through the walls of 
fireplaces or flues could ignite it. Therefore when installing the stove in the presence of 
combustible materials due account must be taken of the guidance on the separation of 
combustible material given in Building Regulations Approved Document J and also in 
these stove instructions. 
If it is found that there is excessive draught in the chimney then a draught stabiliser should 
be fitted. Fitting of a draught stabiliser will affect the requirement for the permanent air 
supply into the room in which the stove is fitted in accordance with Approved Document J 
(see also combustion air supply). 
Adequate provision e.g. easily accessible soot door or doors must be provided for 
sweeping the chimney and connecting fluepipe where it is not intended for the chimney to 
be swept through the appliance, also to permit visual checks on the integrity of the flue 
when the appliance is serviced. 
Hearth 
The hearth should be able to accommodate the weight of the stove and its chimney if the 
chimney is not independently supported. The weight of the stove is indicated in the 
brochure. 
The stove should always be installed on a non­combustible hearth of a size and 
construction that is in accordance with the provisions of the current Building Regulations 
Approved Document J. 
The clearance distances to combustible material beneath, surrounding or upon the hearth 
and walls adjacent to the hearth should comply with the guidance on the separation of 
combustible material given in Building Regulations Approved Document J and also in 
these stove instructions. 
If  the  stove  is  to  be  installed  on  a  combustible  floor  surface,  it  must  be  covered  with  a 
non­combustible  material  at  least  12mm  thick,  in  accordance  with  Building  Regulations 
Approved Document J, to a distance of 30 cm in front of the stove and 15 cm to each side 
measuring from the door of the combustion chamber.