RAIS RINA Instructions For Installation, Use And Maintenance Manual page 10

Rina, viva series
Table of Contents

Advertisement

ENGLISH 
RAIS ­ manual for Rais Rina & Rais Viva 
Combustion air supply 
In order for the stove to perform efficiently and safely there should be an adequate air 
supply into the room in which the stove is installed to provide combustion air.  This is 
particularly necessary if the room is double­glazed or a flue draught stabiliser is 
operating in the same room as the appliance. It may be necessary to increase the air 
vent size in property with low air permeability ( < 5.0 m 
/(h.m 
). 
The provision of air supply to the stove must be in accordance with current Building 
Regulations Approved Document J. An opening window is not appropriate for this 
purpose. 
IMPORTANT NOTE: If applicable and the appliance is being fitted within an existing 
fireplace recess, specialist advice should be sought before fitting any permanent 
ventilation within this area. 
Connection to chimney 
Stoves may have a choice of either a rear or top flue gas connector that allows 
connection to either a masonry chimney or a prefabricated factory made insulated metal 
chimney in accordance with their instructions. In some cases it may be necessary to fit 
an adaptor to increase the diameter of the flue to the minimum required 150 mm section 
of the chimney or liner. 
Electrical Services 
The installation of any electrical services during the installation of this appliance must be 
carried out by a registered competent electrician and in accordance with the 
requirements of the latest issue of BS 7671 
Carbon Monoxide Alarm 
A carbon monoxide alarm complying with BS EN 50292 must be fitted in the same room 
as the appliance. It should be positioned on the ceiling at least 300mm from any wall or, 
if it is located on a wall, as high up as possible (above any doors and windows) but not 
within 150mm of the ceiling. The alarm should also be between 1m and 3m horizontally 
from the appliance.
10 

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

VivaRina 90Viva 98Viva 98 gViva 120Viva 120 g

Table of Contents