RAIS RINA Instructions For Installation, Use And Maintenance Manual page 23

Rina, viva series
Table of Contents

Advertisement

ENGLISH 
RAIS ­ manual for Rais Rina & Rais Viva 
If the stove is fitted in place of an open fire then the chimney will require sweeping 
after a month of continuous operation. This is a precaution to ensure that any 
"softer" deposits left from the open fire usage have not been loosened by the higher 
flue temperatures generated by the closed stove. 
In situations where it is not possible to sweep through the stove the installer will 
have provided alternative means, such as a soot door.  After sweeping the 
chimney the stove flue outlet and the flue pipe connecting the stove to the chimney 
must be cleaned with a flue brush. 
Special Notes for use in a Smoke Control Area (Rais Q­Tee): 
Refuelling on to a low fire bed 
If there is insufficient burning material in the firebed to light a new fuel charge, 
excessive smoke emission can occur. Refuelling must be carried out onto a 
sufficient quantity of glowing embers and ash that the new fuel charge will ignite in 
a reasonable period. If there are too few embers in the fire bed, add suitable 
kindling to prevent excessive smoke 
Fuel overloading 
The maximum amount of fuel specified in this manual should not be exceeded, 
overloading can cause excess smoke. 
Operation with door left open 
Operation with the door open can cause excess smoke. The appliance must not 
be operated with the appliance door left open except as directed in the 
instructions. 
Dampers left open 
Operation with the air controls or dampers open can cause excess smoke. The 
appliance must not be operated with air controls or dampers door left open except 
as directed in the instructions. 
Periods of Prolonged Non­Use 
If the stove is to be left unused for a prolonged period of time then it should be 
given a thorough clean to remove ash and unburned fuel residues. To enable a 
good flow of air through the appliance to reduce condensation and subsequent 
damage, leave the air controls fully open. 
Extractor fan 
There must not be an extractor fan fitted in the same room as the stove as this can 
cause the stove to emit smoke and fumes into the room. 
Aerosol sprays 
Do not use an aerosol spray on or near the stove when it is alight. 
Use of operating tools 
Always use the operating tools provided when handling parts likely to be hot when 
the stove is in use.