RAIS ­ manual for Rais Q­Tee 
Installation distance to combustible wall 
To find out whether the wall next to where the stove is going to be installed is flammable, 
you should contact your building contractor or the local building authorities. 
The hearth should be able to accommodate the weight of the stove. The chimney must be 
independently supported by wall brackets or a ceiling support plate. The weight of the stove 
is indicated in the brochure. 
The stove should always be installed on a non­combustible hearth of a size and construction 
that is in accordance with the provisions of the current UK Building Regulations Approved 
Document J. 
If the stove is to be installed on a wooden floor, it must be covered with a non­combustible 
material at least 12mm thick, in accordance with UK Building Regulations Approved 
Document J, to a distance of 300 mm in front of the stove and 150 mm to each side 
measuring from the door of the combustion chamber. 
The clearance distances to combustible material beneath, surrounding or upon the hearth 
and walls adjacent to the hearth should comply with the guidance on the separation of 
combustible material given in UK Building Regulations Approved Document J and also in 
these stove instructions. 
Inform the user that the appliance has been commissioned and ready to use and give 
instruction on the safe operation of the stove. 
These Instructions must be left with the user and the user should be instructed to keep them 
in a safe place.