Page 1
• Noteable Features • Specifications • Installation • Operation • Maintenance • Warranty Living Air Electronic Air Purification Systems 100, 110, 220/240 volt Flair Systems ™ EcoQuest International ® 310 T. Elmer Cox Drive • Greeneville, TN 37743 • 423.638.7246 www.EcoQuest.com...
Warranty ............Please record the serial number of your Flair: Serial # __________________________________________________________ Please record the name and phone of your EcoQuest Dealer: Name ___________________________________________________________ Phone ___________________________________________________________ CAUTION! - Disconnect power cord before servicing.
• Adjustable Ozone Control • Balanced Ion Production Electrical: • 100 50/60 • 110 volt 60hz AC line operation (Flair 110 volt) • 220 volt 50hz AC line operation (Flair 220 volt) • 240 volt 50hz AC line operation (Flair 240 volt) •...
The Flair reproduces the natural conditions found in the outdoors. It is not designed to create an artificial environment. The re-establishment of a natural environment takes place out in the air, rather than inside the unit.
4. Re-install lint screen as shown below. NOTE: The Flair’s SynAirG purification plates 2 Screws should only be used in the Flair system. (220 & 240 volt only) CAUTION: Do not operate unit without one or both SynAirG purification plate(s) properly installed.
The Flair is most effective when placed in a position that allows the ions and ozone to be mixed evenly and thoroughly with the polluted air. Suggested locations, listed in the order of preference: 1.
SETTING AND ADJUSTING CONTROLS 1. FAN CONTROL The disbursement of cleansing properties is best accomplished with good air circulation. The fan control should be set as high as possible without creating an undesirable noise level. This will be determined by personal preference and the distance you wish the cleansing properties to be dispersed.
MAINTENANCE Periodic maintenance is required to insure that the Flair operates properly. A severely polluted environment can foul an SynAirG purification plate in as little as two weeks or as long as a year. Shown here are basic maintenance procedures that should be carried out to keep your unit running at top performance.
Removing the Chassis & Changing the Fuse: CAUTION: Unplug unit from AC outlet A) Remove the chassis from the cabinet by first removing the screw on the bottom of the cabinet. B) Slide the chassis out and place it on its side. C) The fuse holder is located on the right front side of the circuit board.
Page 10
Troubleshooting - What to look for first. 1. I have plugged in the unit, turned "ON" the power switch and nothing happens…what's wrong? • Make sure the electrical outlet is working properly. • Check the lint screen located at the back to ensure that the safety switch activator clip depresses the safety switch.
Page 11
• Are the filter and fan housing clean? If your unit fails to operate properly after performing trouble-shooting, contact your EcoQuest Independent Distributor for further assistance, contact EcoQuest at the address located on the front of the manual, or visit www.EcoQuest.com for additional technical support.
If you have any questions concerning your Living Air system, please see your local EcoQuest Dealer. If your unit is defective, please contact EcoQuest International, 310 T. Elmer Cox Drive, Greeneville, TN 37743 or visit www.EcoQuestIntl.com for technical help. Did you forget to register your Flair? By registering, you’ll activate your warranty, and your privacy is guaranteed.