Editing The Master Comp/Eq Settings; Gain Reduction Meter And Output Meter; Restoring The Settings To Their Default Values - Roland V-Drums TD-20X Owner's Manual

Percussion sound module
Table of Contents

Advertisement

Chapter 4. Effect Settings

Editing the Master Comp/EQ Settings

1.
Press the [MASTER COMP/EQ] button.
The [MASTER COMP/EQ] button lights.
fig.04-011-mastercomp.eps_70
2.
Use the [F2], [F3], or [CURSOR] buttons to select the
parameter.
3.
Use the [-] [+] buttons or the [VALUE] dial to adjust
the setting.
Parameter
Value
[F2 (M COMP)] button
Threshold
-48–0 (dB)
Gain
-24– +24 (dB)
1:1, 2:1, 3:1, 4:1,
8:1, ∞:1
Ratio
If "Ratio" is set to "1:1" the master comp effect will
not be applied (only the Gain setting will be
valid), regardless of the other settings.
Knee
SOFT, HARD
Attack
0.1, 0–100 (ms)
Release
10–100 (ms)
[F3 (M EQ)] button
SHELV
(Shelving),
Type
PEAK
(MID: fixed to
"PEAK")
0.5–8.0 (only
Q
when Type is
set to "PEAK")
20–1k (LOW),
Freq
20–16K (MID),
(Frequency)
1k–16k (HIGH)
(Hz)
66
Description
Volume level at which
compression begins
Output volume of compressor
Compression ratio
The sound's attack at the
moment compression begins.
Time from when the volume
goes up the threshold level
until the compressor effect
applies
Time from when the volume
falls below the threshold level
until the compressor effect no
longer applies
Entire range above/below the
selected frequency range is
boosted/cut
The vicinity of the selected
frequency range is boosted/
cut
Width of the frequency range
A higher Q narrows the
affected area.
Point at which the boost/cut
will occur
Parameter
Value
Gain
-12– +12 (dB)
The sound may be distorted in a certain setting.
You can choose whether the master compressor/
equalizer settings will be independent for each kit, or be
shared for all kits (p. 112).

Gain Reduction Meter and Output Meter

In the "F2 (M COMP)" screen, the "Gain Reduction Meter" and
the "Output Meter" are displayed.
The "gain reduction meter" shows the change in level (dB)
produced by the master compressor.
The "output meter" shows the output level following the
master compressor and EQ.
Adjust the master compressor's "Gain" so that the output
meter does not exceed 0 dB (i.e., so that it does not clip).
fig.04-012-mastercomp.eps_70
The output meter shows only the level of the output
signal from the MASTER OUT jacks and DIGITAL OUT
jack. It does not show the level of the output signal from
the PHONES jack or the DIRECT OUT jacks.
Restoring the Settings to Their Default
Values
Here's how to restore the master compressor settings to the
default state (an appropriate amount of effect). For details on
the actual values, refer to the "Master compressor setting
examples" below.
1.
Press the [MASTER COMP/EQ] button.
The [MASTER COMP/EQ] button will light.
2.
Press the [F5 (DEFAULT)] button.
A confirmation screen will appear.
3.
Press the [F5 (EXECUTE)] button to execute.
In the "M EQ" screen, pressing the [F5 (DEFAULT)]
button will set the master EQ "Gain" to "0."
Description
Amount of boost/cut
Gain reduction meter
Output meter

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents