Luminance Uniformity; Color Uniformity; Color Primaries; Gamma - Christie Mirage M Series Setup Manual

Mirage m series
Hide thumbs Also See for Mirage M Series:
Table of Contents

Advertisement

Section 6: Specifications

6.1.4 Luminance Uniformity

Dual lamp Full white ANSI 13-pt. (w/o electronic corr.)
Single lamp Full white ANSI 13-pt. (w/o electronic corr.)
Full white ANSI 13-pt. (w/ electronic corr.)
Full black ANSI 13-pt.

6.1.5 Color Uniformity

Full white ANSI 13-pt.
Full black ANSI 13-pt.

6.1.6 Color Primaries

ANSI 9 point measurement

6.1.7 Gamma

Default Gamma (all points from 10 to 90
IRE)
Adjustable Gamma range

6.1.8 Grayscale/Color Resolution

Resolution

6.1.9 Color Temperature

White Default CCT
Range of Adjustment
Tracking (deviation from normal over full
range from 10 – 100 IRE)
Stability (during rated lamp life)
6-2
+15%, -25%
+25%, -35%
+5%. -5%
Negative uniformity shall be
between -35% and 0% and
positive uniformity shall be
between 0% and +35%.
±0.005 cluster on u',v' chart (CIE 1976)
±0.075 cluster on u', v', chart (CIE 1976)
x
Red
0.665 ± .025
Green
0.343 ± .040
Blue
0.145 ± .020
White
0.300 ± .050
2.2 + linear segment
1.0 to 3.0
10 bits (non-linear) min. (Gamma encoded)
7700K ±2000K 350W Lamp
8900K ±2000K 200W Lamp
3200 K - 9300 K
±500 K max
±500 K max
y
0.335 ± .025
0.640 ± .040
0.050 ± .025
0.300 ± .050
Mirage M Series Setup Guide
020-100592-02 Rev. 1 (11-2010)

Advertisement

Table of Contents
loading