6. MAINTENANCE

6.1 Ash Disposal and Removal:

CAUTION: Be sure the fire is out and stove is cold before removing ashes!
Be careful when you empty the fireplace for ashes. There may be glows left as long as 24 hours
after the stove was last used. Ashes should be placed in a metal container with a tight fitting lid.
The closed container of ashes should be placed on a non-combustible floor or on the ground
well away from all combustible materials, pending final disposal.
If ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retrained
in the closed container until all cinders have thoroughly cooled.

6.2 Cleaning of fireplace:

The fireplace is cleaned with a moist
cloth.
Senotherm spray touch up paint is available for
repair of possible damages/ scratches. As there may be minor color differences, it is
recommended to repair large areas with natural borders. You will get the best result if the
fireplace is repaired while it is lukewarm (if the fireplace is too hot the paint will be granular).
Remember a good airing during the repair. A possible change of color to gray is caused by
over-firing, i.e. you have used more wood than recommended. THE SPRAYING OF THE
FIREPLACE MUST BE DONE BY AN AUTHORISED DEALER!

6.3 Removing Baffle Cassette for Cleaning:

Be sure that the fire is out and the fireplace is cold before removing the baffle cassette.
The placement of firebricks, skamol liners and baffle cassette of your SCAN DSA fireplace is
illustrated on the following pages. Removal of all firebricks, skamol liners and the baffle cassette
should follow in the reverse numeric order (e.g. follow step 5 to 1 see below). Installation of all
firebricks, skamol liners and baffle cassette should follow in the reverse order of the removal
that is step 1 to 5.
WARNING:
DO NOT OPERATE INSERT WITHOUT
BAFFLE PLATES PROPERLY INSTALLED
OR WARRANTY WILL BE VOID