Cabinet High Limit Thermostat - ALLIANCE AT050L Service Manual

Drying tumblers
Hide thumbs Also See for AT050L:
Table of Contents

Advertisement

To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.

43. CABINET HIGH LIMIT THERMOSTAT

Refer to Figure 6.
a. Disconnect electrical service to tumbler.
b. Remove lint compartment door.
c. Remove two screws holding thermostat
mounting bracket to cylinder shroud.
d. Remove two screws holding cover to mounting
bracket.
e. Disconnect two wires from thermostat.
f. Remove two screws holding thermostat to
mounting bracket.
CABINET
HIGH LIMIT
BRACKET
70269301
CABINET
HIGH LIMIT
THERMOSTAT
COVER
THERMISTOR
BRACKET
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
g. To remove thermostat wire assembly.
(1) Pull wires through bushing in thermostat
mounting bracket and then push wire out
through hole in back of lint compartment.
(2) Remove junction box cover from rear of
tumbler.
(3) Disconnect wires from inside of junction
box and pull wires from junction box.
NOTE: Refer to wiring diagram when reconnecting
thermostat wires.
THERMISTOR
COVER
Figure 6
Section 5 Service Procedures
TMB1806B
W002
41