Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.

42. STOVE HIGH LIMIT THERMOSTAT

(Gas Models)
a. Remove two screws holding thermostat and
bracket to rear side of stove. Refer to Figure 4.
b. Remove two screws holding cover to mounting
bracket. Refer to Figure 5.
c. Disconnect wires from thermostat.
d. Remove two screws holding thermostat to
mounting bracket. Refer to Figure 5.
SCREWS
40
MOUNTING
BRACKET
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
CONDUIT
JUNCTION
BOX
COVER
STOVE
HIGH LIMIT
THERMOSTAT
Figure 5
NUT
HIGH LIMIT
SCREWS
THERMOSTAT
Figure 4
SCREWS
TU026-SV
W002
STOVE
T025SE1A
70269301