Grounding The Installation; Making The Odu Connection At The Ptp 600 Series Bridge Pidu Plus - Motorola PTP 600 Series User Manual

Point-to-point wireless bridge
Hide thumbs Also See for PTP 600 Series:
Table of Contents

Advertisement

7.7.6

Grounding the Installation

The Outdoor Unit (ODU) must be properly grounded to protect against power surges. It is the
user's responsibility to install the equipment in accordance with Section 810 of the National
Electric Code, ANSI/NFPA No.70-1984 or Section 54 of the Canadian Electrical Code or the
National Electrical Code in the country of installation. These codes describe correct
installation procedures for grounding the outdoor unit, mast, lead-in wire and discharge unit,
size of grounding conductors and connection requirements for grounding electrodes. It is
recommended that installation of the outdoor unit be contracted to a professional installer.
See Section 10 "Lightning Protection" for recommended grounding kits".
7.7.7

Making the ODU Connection at the PTP 600 Series Bridge PIDU Plus

The ODU is connected to the PIDU Plus by means of a concealed RJ45 connector. The RJ45
connection has been placed inside the PIDU Plus hinged cover to prevent the user from
inadvertently plugging other equipment into the ODU RJ45 socket.
Warning: Plugging other equipment into the ODU RJ45 socket may damage the equipment
due to the non-standard techniques employed to inject DC power into the 1000BaseT
connection between the PIDU Plus and the ODU. Plugging the ODU into other equipment
may damage the ODU and/or the other equipment.
Step 1: Undo the retaining screw and hinge
back the cover.
Step 2: Plug in the ODU into the PIDU Plus
Cable ensuring that it snaps home
58

Advertisement

Table of Contents
loading

This manual is also suitable for:

Motowi 4 ptp 600 series

Table of Contents