21.1.2 Wireless 5.8GHz Variant
Radio Technology
RF Band
Channel Selection
Dynamic Frequency Control
Channel size
Manual Power Control
Receiver Noise Figure
Specification
5.725-5.850GHz
By dynamic frequency control and manual intervention
Automatic detection on startup and continual adaptation to
avoid interference.
Initial capture 10-15 sec. Out of service on interference 100
ms.
30 MHz
Maximum power can be controlled lower than the power
limits shown above in order to control interference to other
users of the band.
Typically 6 dB
231