PTP
600
Bridge - Integrated
PTP
600
Bridge
Connectorized
Note: When the connectorized version of 600 Series bridge is used with external antennas,
the figures from the antenna manufacturer for lateral force should be included to calculate to
total loading on the mounting structure.
12.3 Capabilities of the PTP 600 Series Bridges
The structure and mounting brackets of the PTP Series systems are capable of withstanding
wind speeds up to 151mph (242 kph). The installer should ensure that the structure to which
the 600 Series bridge is fixed to is also capable of withstanding the prevalent wind speeds
and loads.
12.4 Wind Speed Statistics
Installers are recommended to contact the national meteorological office for the country
concerned to identify the likely wind speeds prevalent at the proposed location. This will
enable the installer to estimate the total wind loading on the support structures.
Examples of the sort of statistics that are available are:
USA - Reported Fastest Single Wind Velocities for Selected U.S. Cities
(Source: National Weather Service)
City, State
Bismarck, North Dakota
Buffalo, New York
Largest Surface
Area (sq m)
Series
0.130
Series
0.093
-
Table 19 - Lateral Force – Metric
Lateral Force (kg) at wind speed (m/s)
30
40
12
22
9
16
Wind Velocity
169
50
60
34
49
24
35
(mph)
72
91
70
66
48