Figure 24 - Ptp 600 Series Pidu Plus Drip Loop Configuration - Motorola PTP 600 Series User Manual

Point-to-point wireless bridge
Hide thumbs Also See for PTP 600 Series:
Table of Contents

Advertisement

WARNING: The PIDU Plus is not waterproof and should be mounted away from sources of
moisture. If mounted outdoors, the unit should be mounted in a rain proof enclosure,
preferably ventilated.
It is also recommended that you fit a drip loop on the PIDU Plus to ODU cable to ensure that
any moisture that runs down the cable into the cabinet or enclosure cannot enter the PIDU
Plus. As shown in Figure 24. The network connection and mains cable should be treated in
the same way if there is a risk that they can carry moisture to the PIDU Plus.
Figure 24 – PTP 600 Series PIDU Plus Drip Loop Configuration
61