Table of Contents

Advertisement

SEBU8732
Illustration 83
Typical example
(A) Alignment postion
(B) Alignment postion
3. Remove the filter element (4). Remove the seal (5).
Note: The bottom cap has a section that allows
access in order to remove the seal.
4. Install a new seal (5). Install a new filter element
into the bottom cap (2).
5. Align position (A) on the top cap to position (B) on
the filter element. Refer to illustration 83 .
6. Install the assembly of the filter element and the
bottom cap (2). Rotate the bottom cap by hand
clockwise until the bottom cap locks into the locked
position on the breather body. Ensure that the
alignment marks (X and Y) are correctly aligned.
Refer to illustration 82 .
7. Install tube connection (1). Ensure that the
retaining clips on the tube connection are correctly
engaged. Remove the container.

Check the System

Illustration 84
Typical example
Inspect the breather tube (1) for damage. Ensure that
the outlet (2) is clean and free from any obstructions.
Ice can cause obstructions in adverse weather
g03090968
conditions.

Engine Mounts - Inspect

Note: The engine mounts may not have been
supplied by Perkins . Refer to the OEM information
for further information on the engine mounts and the
correct bolt torque.
Inspect the engine mounts for deterioration and for
correct bolt torque. Engine vibration can be caused
by the following conditions:
• Incorrect mounting of the engine
• Deterioration of the engine mounts
• Loose engine mounts
Any engine mount that shows deterioration should be
replaced. Refer to the OEM information for the
recommended torques.