SEBU8732
(Table 5, contd)
The system must be fault free for 40 hours before the system will reset to zero. If the fault is intermittent, and returns within the 40 hours, then the
repeat inducement time will be triggered.
The override can only be used once.
Repeat Inducement
None
time
Inducement
None
Notification
None
Contact your Perkins dealer or your Perkins Distributor at level 1 warning, do not let the fault develop.
World-Wide DEF Level Warnings
Two options are available but only one option will be
enabled.
• The low-level warning lamp will operate when DEF
level reaches the trigger point of below 19 percent.
• At Level 1 the low-level warning lamp in the DEF
gauge will illuminate and the emission malfunction
lamp will be on solid.
• At Level 2 the low-level warning lamp for the DEF
is active and the emission malfunction lamp will
flash.
• At Level 3 all level 2 warning are operating, plus
the stop lamp will become activate. The engine will
shut down or will only operate at 1000 RPM.
Filling the DEF tank will remove the warning from the
system.
Table 6
-
Normal operation
Inducement Trigger
Above 19 percent
Inducement
None
Notification
None
Table 7
-
Normal operation
Inducement Trigger
Above 19 percent
48 minutes
20 minutes
None
None
Emission malfunction
Emission malfunction
lamp will be on solid
lamp will flash
World-Wide DEF Level Option 1
Initial indication
Level 1
Below 19 percent
Below 12.5 percent
None
None
Low-level lamp
Low-level lamp
illuminated
illuminated
Emission malfunction
lamp on solid
World-Wide DEF Level Option 2
Initial indication
Level 1
Below 19 percent
Below 12.5 percent
Features and Controls
Selective Catalytic Reduction Warning System
Shut down or idle
Until fault heals
Emission malfunction
lamp will flash
The stop lamp will
activate
Level 2
0 Percent reading
25 percent torque de-
rate
Low-level lamp
illuminated
Emission malfunction
lamp flashing
Level 2
6 Percent reading
39
Cycling the keyswitch
will give 20 minutes of
full power
Emission malfunction
lamp will flash
Level 3
Empty tank
Shut down or idle only
Low-level lamp
illuminated
Emission malfunction
lamp flashing
Stop lamp on solid
Level 3
0 Percent reading
(continued)