Note: For security reasons, all existing audit events are not deleted.
The lock is now set to the factory-configured setup with the default factory
master code, 1,2,3,4,5,6,7,8. Important: Before you can program the lock
you must first enter a new 8 digit master code of your choice.
For example, if your new code is 1,3,5,7,2,4,6,8, the correct buttons to
press in the exact order are:
#1,2,3,4,5,6,7,8,#,0,0,0,#,1,3,5,7,2,4,6,8,#,1,3,5,7,2,4,6,8,#,#
To determine if you have successfully changed your master code, enter
1,3,5,7,2,4,6,8, and the lock should open. Now try the factory master
code, 1,2,3,4,5,6,7,8, and the lock should not open.
Refer to the included Operations Manual for further programming
instructions.
M. INSTALLING THE STRIKE
Note: The latch and strike provided must be used.
M-1 Mark location of strike on the door frame,
making certain that the strike opening is
aligned (a) with latch bolt.
M-2 Mortise doorframe for strike
minimum to dimensions shown. Secure strike
(b) to the door frame using two 1" (25 mm)
combination screws (c) (supplied).
14
1
/
" (31mm)
1
4
c
" (3 mm) deep
3
32
b
Caution: Check the operation of the latch by
making sure that the deadlatch (a) stops
against the strike (b) as shown and does not
slide into the strike opening when the door
is closed. If that situation occurs, then a
total lockout may occur. This will void our
warranty of the complete lock mechanism.
If necessary, correct the door over-travel by
using the rubber bumpers as described in
Section N (Installing Rubber Bumpers).
N. INSTALLING RUBBER BUMPERS
N-1 Close the door and apply pressure making sure
the deadlatch (a) rests on the strike plate (b) as
shown. Standing on the frame (door stop) side
of the door, check for gaps between the door
and the frame on the three sides of the frame
(left, right, and top).
a
N-2 Mark locations where the gaps are
approximately
locations are free from grease and dust.
Peel the bumpers (c) (supplied) from their
protective backing without touching the
adhesive surface and stick them on the
marked locations.
3
/
" (84mm)
3
8
Note: Allow 24 hours for adhesive to set before testing. The door may be
operated normally during this time.
4
" (124mm)
7 /8
" (5 mm). Make sure these
3
16
a
Correct
b
a
Incorrect
b
c
15