10-3. Selecting Welding Power Source Range

NOTE
Access
Setup
Display
Press Mode
Select
Default values are for 450 Ampere Inverter Model.
Do not change values if using 450 Ampere
Inverter Model.
*Use Parameter Select button to
select voltage or amperage.
Use Increase/Decrease buttons
to change value.
5*
OM-172 324 Page 34
Welding power source minimum and maximum voltage values are always
required. Amperage values are required for pulse welding.
>R a n g e
S e c u r i t y
A c c e s s
M i g
T y p e
2
>A m p
M a x
5 6 5
A m p
Parameter
Select
Figure 10-3. Range Display
1
1
See welding power source Owner's
Manual for voltage and amperage
ranges. Set values to match weld-
ing power source ranges.
>V o l t
M i n
1 0 . 0 V o l t
2
Range is 0 to 25.0 volts.
3
Range is 25.0 to 99.9 volts.
4
Parameter
Select
Range is 0 to 50 amperes.
5
V o l t
M i n
>1 0 . 0 V o l t
Range is 150 to 999 amperes.
Increase/Decrease
V o l t
M i n
> 8 . 0 V o l t
Parameter
Select
Increase
3*
>V o l t
M a x
3 8 . 0 V o l t
Parameter
Select
4*
>A m p
M i n
1 0
A m p
Range Display
Minimum Voltage Display
Maximum Voltage Display
Minimum Amperage Display
(Available When System Set
For Pulse/Mig)
Maximum Amperage Display
(Available When System Set
For Pulse/Mig)