Miller Robotic Interface II Owner's Manual page 20

Controls welding power source for robotic welding applications
Hide thumbs Also See for Robotic Interface II:
Table of Contents

Advertisement

P r o c e s s
C a r d
>S e q u e n c e
Mode Select
>P r e f l o w
0 . 0
Set Desired Weld Sequence
OM-172 324 Page 14
>P r e f l o w
0 . 0
1
3
S e c
Parameter
Select
Figure 6-2. Setting Preflow Sequence Display
Set Desired Weld
W e l d
Sequence Trim
>5 0
2 0 0
Increase/
Decrease
W e l d
Wire Feed Speed
6 0
>2 0 0
Increase/
Decrease
W e l d
6 0
3 0 0
Figure 6-3. Setting Weld Sequence Display
S e c
Parameter
Select
P r e f l o w
>0 . 0
S e c
Set Desired Time
Parameter
Select
Increase/
Decrease
1
T r i m
I P M
Parameter
Select
T r i m
I P M
Parameter
Select
T r i m
Increase
Proceed to next figure.
I P M
1
Mode Select Button
When unit is turned On, Process is
the default mode, at other times,
use mode select button to select
Sequence.
2
Parameter Select Button
Use parameter select button to se-
lect parameters.
3
Preflow Parameters Display
2
Preflow can be adjusted from 0-9.9
seconds. If value set is zero (0),
there is no Preflow sequence.
Go to Figure 6-3.
>P r e f l o w
1 . 2
S e c
Increase
Proceed to next figure.
1
Weld Parameters Display
Parameter ranges are as follows:
Trim (Arc Length), 0-99
Wire Feed Speed, 50-780 Inches
Per Minute, IPM
Go to Figure 6-4.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Robotic Interface II and is the answer not in the manual?

Questions and answers