Miller Robotic Interface II Owner's Manual page 31

Controls welding power source for robotic welding applications
Hide thumbs Also See for Robotic Interface II:
Table of Contents

Advertisement

1
>S t a r t
0 . 2
S e c
2 4 . 0 V o l t
9 0
I P M
Parameter
Select
Increase
Proceed to next figure.
S t a r t
>0 . 5
S e c
2 4 . 0 V o l t
9 0
I P M
Set Desired Time
Parameter
Select
Increase/
Decrease
>S t a r t
0 . 5
S e c
1 8 . 0 V o l t
2 0 0
I P M
Parameter
Select
Figure 8-4. Setting Start Sequence Display
1
Set Desired Voltage
W e l d
>1 8 . 0 V o l t
2 0 0
I P M
Increase/
Decrease
Parameter
Select
Set Desired Wire Feed Speed
W e l d
2 0 . 0 V o l t
>2 0 0
I P M
Increase/
Decrease
Parameter
Select
>We l d
2 0 . 0 V o l t s
4 2 0
I P M
Increase
Proceed to next figure.
Figure 8-5. Setting Weld Sequence Display
1
Parameter ranges are as follows:
Seconds, 0-2.5 Sec. If value set is
S t a r t
zero (0), there is no Run-In
sequence.
0 . 5
S e c
>1 8 . 0 V o l t
Volts, 10.0-38.0 Volts
9 0
I P M
Wire Feed Speed, 50-780 inches
per minute, IPM
Set Desired Voltage
Go on to Figure 8-5.
Increase/
Parameter
Decrease
S t a r t
0 . 5
S e c
1 8 . 0 V o l t
>2 0 0
I P M
Set Desired
Wire Feed Speed
Increase/
Decrease
1
Parameter ranges are as follows:
Volts, 10.0-38.0 Volts
Wire Feed Speed, 50-780 Inches
Per Minute, IPM
Go to Figure 8-6.
Start Parameters Display
Select
Weld Parameters Display