>C r a t e r
0 . 0 2 S e c
2 4 . 0 V o l t
9 0
I P M
Parameter
Select
C r a t e r
>0 . 1 2 S e c
2 4 . 0 V o l t
9 0
I P M
Set Desired Time
Increase/
Decrease
1
>B u r n b a c k
0 . 0 0
S e c
1 8 . 0
V o l t
Parameter
Select
OM-172 324 Page 26
1
C r a t e r
0 . 1 2 S e c
>1 8 . 0 V o l t
9 0
I P M
Set Desired
Parameter
Voltage
Select
Increase/
Decrease
Figure 8-6. Setting Crater Sequence Display
B u r n b a c k
>0 . 1 2
S e c
1 8 . 0
V o l t
Parameter
Set Desired Time
Increase/
Decrease
Figure 8-7. Setting Burnback Sequence Display
C r a t e r
0 . 1 2 S e c
1 8 . 0 V o l t
>2 0 0
Set Desired
Parameter
Wire Feed Speed
Select
Increase/
Decrease
>C r a t e r
0 . 1 2 S e c
1 8 . 0 V o l t
2 0 0
Increase
Proceed to next figure.
B u r n b a c k
0 . 1 2
S e c
>1 6 . 0
V o l t
Set Desired
Select
Burnback Volts
Increase/
Decrease
1
Crater Parameters Display
Parameter ranges are as follows:
Seconds, 0-2.50 Sec. If value set is
zero (0), there is no Crater
sequence.
Volts, 10.0-38.0 Volts.
Wire Feed Speed, 50 to 780 inches
per minute, IPM.
Go to Figure 8-7.
I P M
Parameter
Select
I P M
1
Burnback Parameters Display
Parameter ranges are as follows:
Volts, 10.0-38.0 Volts
Seconds, 0-0.25 seconds. If value
set is zero (0), there is no Burnback
sequence.
Go to Figure 8-8.
>B u r n b a c k
0 . 1 2
1 6 . 0
Parameter
Select
Increase
Proceed to next figure.
S e c
V o l t