Operating At Low Speed - YASKAWA VS-606V7 Series Instruction Manual

Compact general-purpose inverter (voltage vector control)
Hide thumbs Also See for VS-606V7 Series:
Table of Contents

Advertisement

FREQUENCY
REFERENCE
FWD (REV) RUN/STOP
MULTI-STEP SPEED REF. 1
(TERMINAL S5)
MULTI-STEP SPEED REF. 2
(TERMINAL S6)
MULTI-STEP SPEED REF. 3
(TERMINAL S7)
16-Step speed operation
Set frequency reference 9-16 to n120-127.
Set input terminal to multi-step speed reference for multi-function input
selection.

Operating at low speed

By inputting a jog command and then a forward (reverse) run command,
operation is enabled at the jog frequency set in n032. When multi-step
speed references 1, 2, 3 or 4 are input simultaneously with the jog
command, the jog command has priority.
Constant No.
n032
Jog frequency
n050 to n056
Jog reference
52
(n027) 40.0 Hz
(n026) 35.0 Hz
(n025) 30.0 Hz
(n024) 25.0 Hz
ON
Name
Initial setting : 6.00Hz
Set to "10" for any constant.
(n031) 60.0 Hz
(n030) 55.0 Hz
(n029) 50.0 Hz
(n028) 45.0 Hz
ON
ON
ON
ON
ON
Setting
TIME
ON
ON