Verify Function - YASKAWA VS-606V7 Series Instruction Manual

Compact general-purpose inverter (voltage vector control)
Hide thumbs Also See for VS-606V7 Series:
Table of Contents

Advertisement

VERIFY function

Collates the constants stored in the digital operator with the constant in the
inverter. As well as write-in, VERIFY is possible only for the inverters with
same product series, power supply specifications and control mode (V/f
control or vector control).
When the constants stored in the digital operator correspond to those in the
inverter, vFy is displayed by blinking, then End is displayed.
Constants added with software version upgrades will be displayed when
VERIFY is performed for VS-606V7 Inverters without the additional
constants and VS-606V7 Inverters with the additional constants.
The constants added with each software version upgrade are shown in the
following table.
Software No.
VSP010015
VSP010020
VSP010024
Refer to page 160 (Constants List) for details.
[Example] Collate the constants stored in EEPROM inside the digital
operator with the constants in the inverter
• Enable the setting for the
constans n001 to n179.
• Execute VERIFY by Constant
Copy Function selection
(n176).
n175
n077, n078, n079, n115, n116
n040, n041, n042, n043, n044, n064, n101, n102, n117,
n118, n119, n166, n167, n168, n169, n173, n174
Explanation
• Press DSPL to light [PRGM].
• Press ENTER to display the
set value.
• Change the set value to 4 by
Pressing
or
v
• Press ENTER.
• Change the constant No. to
n176 by pressing
• Press ENTER to display the
set value.
• Change the set value to vFy by
pressing
or
v
• Press ENTER.
Additional Constants
Operator display
N001
(Can be a different constant No.)
1 (Lit)
(Can be a different constant No.)
4(Bl inks)
key.
4(Lit for one second)
N001 (The constant No. is
displayed)
N176
v
or
key.
DY (Lit)
VFY (Lit)
key.
VFY (Blinks while executing
VERIFY)
117

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents