Error Log

The error log records the last 6 "2X Paper Jam" or "9XX Service"
errors. In a full log, position 6 is the oldest error. If more than 6 errors
are received, the oldest error is discarded. If the same error occurs
consecutively it is recorded only once.
All 97X Network Card errors are logged as 977.
1. Enter Diagnostics mode.
2. Select [ERROR LOG].
3. Select [CLEAR] and then [CONTINUE] to clear the error log.
4. Press Return to return to Diagnostics mode main menu.

Flash Test

This test writes to and reads from the flash memory. It destroys all
data stored in the flash SIMM.
1. Enter Diagnostics mode.
2. Select [DEVICE TESTS].
3. Select [Flash Test].
The operator panel will display [Passed] or [Failed].
4. Press Return to return to Diagnostics mode main menu.

Fuser Temperature And Warm-Up Time

These settings allow adjustment of the fuser to correct problems
with paper curl or melting letterheads.
Paper curl in which the top and bottom of the page curl toward the
printed side (hot paper curl) can be corrected by reducing the fuser
temperature. Reduce the setting from Normal to No Boost; if
necessary, reduce the setting further to Low Temperature. Verify that
the toner is being adequately fused to the paper at the new
temperature setting.