3.6 Activating Alarms from the Keypad
3.6.1 Personal Attack
Hold down the = button
for 2 seconds.
3.6.2 Fire Alarm
Hold down the ' button
for 2 seconds.
3.6.3 Medical Alarm
Hold down the ; button
for 2 seconds.
3.7 Duress Arming / Disarming
3.7.1 What is a Duress Code?
A duress code is a personal user code that the alarm panel recognises as being entered under duress. By this
we mean that the user has been forcibly made to enter their user code to disarm or arm the panel by another
person.
The alarm panel treats this code like a proper user code and behaves as normal. The duress code will arm or
disarm the system as normal. However, an emergency message is sent to your central monitoring station
indicating that the panel was armed/disarmed under duress.
Reverse the 3
Method 1
example, enter 1 2 4 3 instead of 1 2 3 4.
Enter the duress code as programmed on your system.
Method 2
When you enter the duress code, the panel will act normally, however the duress event will be reported to the
Central Monitoring Station.
3.8 Display Event in FTA Mode
Fragment Indicator
EE
K
pq...qy
K
pq...qy
K X
pq...qy
K Z
PA
K X
F
K Z
qu
K
L
K
pq...qy
K S
Tr
K S
Tt
K S
Ti
K S
Ë = Flashing Icon
NOTE: The numbers of the activated zones which are still open while viewing in FTA mode will be
flashing.
RINS545-7
The Personal Attack alarm will either activate all sounders or will be silent (the
event will only be reported to the Central Monitoring Station) depending on how
the system is programmed by the engineer.
The Fire alarm will activate all sounders. External sounders will emit an intermittent
tone and keypad sounders will emit a series of three rising tones.
The Medical alarm will activate all sounders. Keypad sounders will emit a high
frequency repeated tone.
rd
th
and the 4
digits of your user code when entering it into the keypad. For
Entry time expired after Entry/Exit or Shunt Keypad zone triggered. The system
has not been disarmed within the predetermined time.
Zone ? 01...16 triggered: Access, Immediate or 24Hr type.
Zone ? 01...16 triggered: Personal Attack type.
Zone ? 01...16 triggered: Fire type.
PA alarm activation from keypad.
Fire alarm activation from keypad
Medical alarm activation from keypad.
Telephone line fail alarm
Zone ? 01...16 triggered: Tamper type.
Expander tamper – the expander module is no longer detected (Matrix 816 only).
Siren tamper – the siren connected to PGM7 is no longer detected
(Matrix 816 only).
Key press tamper – 16 wrong key presses in armed mode.
Meaning
Matrix 6/816 User Manual
Page 11
Need help?
Do you have a question about the MATRIX 6 and is the answer not in the manual?