Frequency Command; A Prior Condition; Example 6 - Frequency Command (In Case Of 60Hz); Example 7 - Frequency Command (In Case Of 50Hz) - Hyundai N100 Instruction Manual

Inverter rs485 interface
Table of Contents

Advertisement

plus
N100
Inverter RS485 Interface Instruction Manual
2.3

Frequency Command

2.3.1

A prior condition

(1) Communication number :
(2) Command
(3) Parameter
2.3.2
Example 6 – Frequency Command (In case of 60Hz)
(1) Transmit Data (In case of 60.00Hz)
Transmit (8Byte)
010600041770C61F
Data Description
(2) Response Data
Response (8Byte)
010600041770C61F
2.3.3
Example 7 – Frequency Command (In case of 50Hz)
(1) Transmit Data (In case of 50.00Hz)
Transmit (8Byte)
010600041388C55D
Data Description
(2) Response Data
Response (8Byte)
010600041388C55D
N100_Inverter RS485 Interface Manual(English).doc
01
(Inverter address 1)
:
06
(Setting request)
:
0004
Com.
Com-
Parameter
Num.
mand
01
06
00
3
2
1
1x16
+ 7x16
+ 7x16
divide by 100
60.00Hz (Parameter value)
Com.
Com-
Parameter
Num.
mand
01
06
00
Com.
Com-
Parameter
Num.
mand
01
06
00
3
2
1
1x16
+ 3x16
+ 8x16
divide by 100
50.00Hz (Parameter value)
Com.
Com-
Parameter
Num.
mand
01
06
00
Data
04
17
0
+ 0x16
= 6000 (Communication Data)
Data
04
17
Data
04
13
0
+ 8x16
= 5000 (Communication Data)
Data
04
13
CRC 16
Hi
Lo
70
C6
1F
CRC 16
Hi
Lo
70
C6
1F
CRC 16
Hi
Lo
88
C5
5D
CRC 16
Hi
Lo
88
C5
5D
14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

N100 plus

Table of Contents