Zone Array; Testing The System; Basic Reporting Reference; Battery Test - Bosch Solution 64 Installer's Manual

Intrusion control panel
Hide thumbs Also See for Solution 64:
Table of Contents

Advertisement

Solution 64 | Installer Guide | Programming Overview
Z one A rra y
The feature allows you to view the condition of all zones on
the panel in banks of 16 zones at a time. From the installer
programing mode press MENU 3-0-1 to access the zone array.
Use the up and down arrow keys to scroll up and down the
zone banks and Press [OK] or [MENU] when finished.
The following information can be displayed depending on the
current zone status.
N= NORMAL
S = SHORTED
A= ALARM
T= TAMPER
- = DISABLED
0000000001111111
1234567890123456
NSA-ANAT--------
PRESS

, OK or MENU
In the above example screen,
N = Zone 01 and 06 are Normal (Sealed)
S = Zone 02 is Shorted
A = Zone 03,05,07 are in Alarm (Unsealed)
T = Zone 08 is in Tamper Alarm (Unsealed)
- = Zone 04, 09-16 are Disabled (Unused)
Te sti ng th e S y s te m
You will need to be in programming mode before accessing
the test functions listed below.
Walk Test
Use the walk test command MENU 3-9-0 to test and verify that
all zones work correctly.
External Audible Test
Use MENU 4-9-0 to test and verify that all horn speakers
operate. This test will sound the horn speaker for two seconds.
Internal Audible Test
Use MENU 4-9-1 to test and verify that all 12 VDC sirens
operate. This test will sound the siren for two seconds.
Strobe Test
Use MENU 4-9-2 To test and verify that the strobe operates.
This test will turn on the strobe until you manually stop the
test.

Battery Test

Use MENU 7-9-1 to test the back-up battery that is connected
to the control panel.

Communication Test

Use MENU 5-9-0 to test the telephone reporting capability of
the control panel. You can also activate a communication test
by holding down the Test / Mail key on the keypad.
4-4
Ba sic Rep ortin g Referen ce
The following table is a shortform point ID listing.
For a complete listing of all the CID and SIA event reporting
information that will be sent by the Solution Control panel
contact your distributor or visit www.Bosch.com.au.
Point ID Table
Ur999
Ur001 - 256
Ur000
Zn999
Zn998
Zn891-898
Zn881-888
Zn871-878
Zn861-868
Zn851-858
Zn841-848
Zn831-838
Zn821-828
Zn811-818
Zn801-808
Zn791-798
Zn001-128
Table 13: Shortform Point ID Listing
Module Description
Installer
Users
Quick Arm
Keyfob Low Battery
Keyfob Panic Alarm
Panels 1-8
Keypads 1-8
Ethernet 1-8
GSM 1-8
Output Expander 1-8
Serial Expander 1-8
Lan P/Supply 1-8
RF Reciever 1-8
Access 1-8
X10 1-8
Lift 1-8
Zones
Bosch Security Systems | 11/05 | BLCC110I

Hide quick links: