Solution 64 | Installer Guide | Device Programming
Devices > Keypads >
Beeper Options
1

Trouble Alerts

2
Entry Warning
3
Exit Warning
4
Chime Tone
5
Display Temperature
6
Reserved
7
Reserved
8
Reserved
The above options can be configured independantly for each
keypad fitted to the system.
1)
Press [MENU] + [6] + [1] + [5] and use the up and down arrows
to highlight the keypad in the list then press [OK].
 Trouble Alert Beeps
 Entry Warning
 Exit Warning
Press  OK ON OFF MENU
2)
Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
3)
Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
Trouble Alerts
Setting this option will cause the keypad to sound a trouble alert tone
to notify the user that the panel has a trouble condition that needs to
be rectified. Press the [OK] to acknowledge the trouble condition and
stop the alert tone. Press the down arrow for more information on the
trouble condition.
i
See MENU 7-7-1 — Area Options if you would like to delay
the audible trouble alert tone during the night when the
panel is used in residential applications.
Note
Entry Warning
Setting this option will cause the keypad to sound an entry warning
alert tone when the entry timer is running. The tone will stop when a
key is pressed or when the entry time expires.
Exit Warning
Setting this option will cause the keypad to sound an exit warning
alert tone when the exit timer is running. The tone will stop when the
timer expires.
Chime Tone
Setting this option will cause the keypad to sound a chime alert tone
when a chime zone is faulted. Chime zones are active when the area
is disarmed and are typically used to monitor the front door of a shop.
The chime alert tone will stop when the zone reseals.
Display Temperature
Setting this option configures the panel to always show the current
keypad temperature in the display. Each keypad can be set to display
its own temperature. It is possible to trigger a temperature alarm
based on the keypad temperature. See MENU 7-7-3 — Keypad Hi/Lo
Temp for more information.
10-4
Devices > Keypads >
MENU 6-1-5
Emergency Keys
Y
1
Y
2
Y
3
Y
4
N
5
N
6
N
7
N
8
The above options can be configured independantly for each
keypad fitted to the system.
1)
2)
3)
Audible Keypad Fire
Setting this option allows the panel to sound an audible alarm when a
Keypad Fire Emergency Alarm has been triggered via the keypad. To
initiate a fire emergency via the keypad, press and hold the [4] + [6]
keys down for two seconds. Enter a valid user PIN to reset the alarm
condition.
Report Keypad Fire
Setting this option allows the panel to send a Fire report to the base
station when a Keypad Fire Emergency Alarm has been triggered via
the keypad.
Audible Keypad Medical
Setting this option allows the panel to sound an audible alarm when a
Keypad Medical Emergency Alarm has been triggered via the keypad.
To initiate a medical emergency via the keypad, press and hold the
[7] + [9] keys down for two seconds. Enter a valid user PIN to reset the
alarm condition.
Report Keypad Medical
Setting this option allows the panel to send a Medical report (event
43) to the base station when a Keypad Medical Emergency Alarm has
been triggered via the keypad.
Audible Keypad Panic
Setting this option allows the panel to sound an audible alarm when a
Keypad Panic Emergency Alarm has been triggered via the keypad. To
initiate a panic emergency via the keypad, press and hold the [1] + [3]
keys down for two seconds. Enter a valid user PIN to reset the alarm
condition.
i
Note
Audible Keypad Fire
Report Keypad Fire
Audible Keypad Medical
Report Keypad Medical
Audible Keypad Panic (Invisible If Not Set)
Report Keypad Panic
Reserved
Reserved
Press [MENU] + [6] + [1] + [6] and use the up and down arrows
to highlight the keypad in the list then press [OK].
 Audible Keypad Fire
 Report Keypad Fire
 Audible Kpad Medical
Press  OK ON OFF MENU
Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
If this option is disabled, a keypad panic alarm will not be visible
on the keypad display (i.e. Invisible Panic Alarm).
Bosch Security Systems | 11/05 | BLCC110I
MENU 6-1-6
Y
Y
Y
Y
N
N
N
N