Install The Optional Fan - Vermont Castings Stardance 3070 Homeowner's Installation And Operating Manual

Stardance direct vent/natural vent gas heater
Table of Contents

Advertisement

Install the Optional Fan

If you are installing the optional convection Fan Kit
#2767 (FK26), continue here. If you are not installing a
Fan Kit, go to page 15, Venting System Assembly.
1. The fan kit includes a Blower Assembly and a
Rheostat Assembly, connected by a cable. (Fig. 18)
The Blower Assembly mounts to the bottom rear of
the stove, and the Rheostat mounts to the valve
coverplate. The assembly includes a 'snapstat' which
automatically turns the fan On (or Off) above (or
below) approximately 109˚. The Rheostat also
provides a range of fan speed settings from Off
(which overrides the snapstat function) to High.
Unpack and inspect the Blower assembly. Confirm
that the fan spins freely.
WARNING
This appliance is equipped with a three-prong
(grounded) plug for your protection against shock
hazard and should be plugged directly into a
properly grounded three-prong receptacle. Do not
cut or remove the grounding prong from this plug.
Not Used on
RF Models
Not Used On
Stardance
Blower
Assembly
ST473
Fig. 18 Fan kit components.
2. Remove the rear skirt insert panel at the bottom of
the Rear Skirt (Fig. 19) and fasten the blower
assembly to the firebox back with the two Phillips
pan-head bolts originally installed in the firebox back.
('1', Fig. 20)
NOTE: Steps 3 and 4 do not apply when the RF
valve is used. After attaching blower assembly to the
firebox, run the spliced female leads to the front of
the stove and attach to back of RF valve. (Page 30,
Fig. 57)
3. Attach the snapstat assembly to the snapstat bracket
with two sheet-metal screws. ('2', Fig. 21) Attach the
snapstat bracket to the stove with a hex-head bolt
passing through the bracket and into the stove base.
('3', Fig. 20)
20003456
Vermont Castings Stardance Direct Vent/Natural Vent Gas Heaterr
Snapstat Bracket
Snapstat/
Extension
Assembly
Rheostat
Assembly
Not Used
on RF
Models
Connect to PC Board on
RF Models Only
4. The rheostat control switch attaches to the left side of
the valve bracket at the front of the stove.
Remove the plug from the rheostat bracket.
Insert the switch box shaft through the hole in the
back of the right side of the valve bracket, aligning the
locator pin with the smaller hole in that bracket.
Attach the control knob to the rheostat shaft.
Use the wire tie to secure the fan and rheostat wire
harnesses together.
Rear Skirt
Sheet Metal
Screws
Rear Skirt
Insert
Fig. 19 Remove rear skirt insert.
Star Washer
Sheet Metal
Screws
Phillips
2
Pan Head
1
Bolts
Star
Washer
Fig. 20 Attach the fan assembly and the snapstat.
Rheostat
Retaining Collar
Rheostat Knob
Fig. 21 Attach the fan rheostat.
ST313
Snapstat
1/4" - 20
Hex bolt
Snapstat
Bracket
3
ST314
Rheostat
ST347a
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents