Fan Kit Installation

1. Attach the fan assembly at the bottom edge of the inner
back with two (2) 1/4-20 x 3/4" hex head screws.
2. Attach snapstat to the mounting holes on the underside
of the bottom with two (2) 1/4-20 pan head screws.
3. Attach the rheostat holder (provided with the stove)
under the right front wing of the bottom heat shield with
two (2) #10 sheet metal screws.
4. Attach the rheostat to its holder by inserting the rheostat
control shaft through the holder hole. Install the retaining
ring and rheostat knob onto the shaft.
5. Secure the rheostat cable to the underside of the bottom
heat shield using the wire tie provided and the hole at the
right rear edge of the heat shield.
6. Fan will not operate until stove reaches approximately
109°F.
Hole for Wire
Tie to Secure
Cable
Rheostat
Knob
Rheostat
Holder
Rheostat
Snapstat
Figure 27 - Fan installation (Kit # 2767).

Installing or Removing Catalyst

1. Remove the access cover by gently lifting up and pulling
out from the bottom edge. (Figure 28)
2. Remove the inner cover by pulling it straight out. (Figure
29)
3. Remove the catalyst by gently pulling it straight out.
(Figure 30) Place the catalyst where the catalyst's
ceramic components will not be damaged.
20
Screws
ST848
fan install
6/05
Vermont Castings • Defiant Flexburn Installation & Operating Manual_R32 • 04/17
Access Cover
Figure 28 - Remove access cover.
Inner Cover
ST1187
remove access cover
Figure 29 - Remove inner cover.
ST1188
remove inner cover
Remove Catalyst
Figure 30 - Remove catalyst.
ST1189
remove catalyst