Install Vent Adapter Pipe (Simpson Dura-Vent Components); Side Wall Termination Assembly - Vermont Castings Stardance 3070 Homeowner's Installation And Operating Manual

Stardance direct vent/natural vent gas heater
Table of Contents

Advertisement

Fig. 25 Fasten outer pipe with #12 x 1/2" sheet metal screw.
Install the Vent Adapter Pipe
(Simpson Dura-Vent Components)
1. Install the Restrictor Plate. Consult the 'Vent Run
Specifications' on page 8 to determine whether the
restrictor plate is needed. If so, put the restrictor
plate in place within the inner flue collar. (Fig. 22)
2. Discard the inner starter pipe shipped with the
logset. Using the starter pipe assembly listed on
page 7, slide the inner section out to allow access.
• Run a bead of sealant around the bottom end of
the starter pipe and attach the assembly to the stove
using three 1/4-20 x 3/8" Phillips screws provided in
the parts bag. (Fig. 26)
3. Install the Outer Adapter Pipe. Apply a 1/4" bead
of cement around the outside surface, about one
inch from the crimped end. (Fig. 27) Orient the
vertical seam to the rear, and insert the crimped end
of the outer pipe into the flue collar. Fasten with
three sheet metal screws provided.
1/4-20 x 3/8
Phillips
Screws
Fig. 26 Simpson Dura-Vent - install inner adapter pipe.
20003456
Vermont Castings Stardance Direct Vent/Natural Vent Gas Heaterr
ST213
Inner Adapter
Pipe
ST355
Fig. 27 Simpson Dura-Vent - install outer adapter pipe.

Side Wall Termination Assembly

1. Locate the vent opening on the wall. Refer to Figure
4, Page 6, to determine the opening centerline. It
may be necessary to first position the stove and
measure to find the hole location. Depending on
whether the wall is made of combustible materials,
cut the opening to the size shown in Figure 29.
Combustible wall openings must be framed as
shown in Figure 28.
9³⁄₈"
CFM System
(240mm)
9³⁄₈"
(240mm)
Combustible Wall
10"
DuraVent
(254mm)
System
10"
(254mm)
VO584-100
Fig. 28 Locate vent opening.
2. Measure the wall thickness and cut the wall sleeve
sections to proper length (MAXIMUM 12"). Assemble
the sleeve with the #8 sheet metal screws supplied.
Attach the firestop plate to the sleeve end with the
holes. (Fig. 29) NOTE: The wall sleeve is required
in combustible walls only.
3. Install the Wall Firestop/Sleeve assembly into the
wall cutout and fasten the firestop to the wall cutout
framing members. (Fig. 29)