Install The Log Set; Connect Gas Supply Line - Vermont Castings Stardance 3070 Homeowner's Installation And Operating Manual

Stardance direct vent/natural vent gas heater
Table of Contents

Advertisement

Vermont Castings Stardance Direct Vent/Natural Vent Gas Heater

Install the Log Set

1. Remove the logs from their packaging, and inspect
each piece for damage. DO NOT INSTALL DAM-
AGED LOGS.
2. Install the rear log centering it side to side on the
sheet metal shelf at the back of the firebox. (Fig. 40)
The log will touch both sides and the back wall of
the firebox.
3. Install the right log by engaging hole on bottom with
pin on the rear log. (Fig. 40) Then set right bottom
side on the burner so the edge of the log touches
the right side of the firebox. The right log does not
use the locator pins on the burner to stay in place.
4. Install the left log by engaging hole on bottom with
pin on rear log. (Fig. 40) Then set left bottom side
on the burner so the edge of the log touches the left
side of the firebox.
5. Loosely sprinkle the lava rocks directly on top of the
burner in front of and between the decorative grate
and the right and left logs. Use the lava rock to
cover brackets on the burner. (Fig. 41)
Left
Log
Rear Log
Fig. 40 Install the back, left and right logs.
22
22
Right
Log
Decorative Grate
LG141
Lava Rock
Fig. 41 Completed log installation.
Connect the Gas Supply Line
Check the Rating Plate attached by a steel cable to the
firebox, to confirm that you have the appropriate firebox
for the type of fuel to be used. The Stardance may be
converted from one gas to another using the appropri-
ate Fuel Conversion Kit listed on page 40.
CAUTION
This appliance should only be
connected by a qualified gas techni-
cian. Test to confirm manifold
pressures as specified below.
The Stardance Heater and its individual shutoff
valve must be disconnected from the gas supply
piping during any pressure testing of that system
at test pressures in excess of 1/2 psig (3.5 kPa).
The Stardance Heater must be isolated from the
gas supply piping system by closing its indi-
vidual manual shutoff valve during any pressure
testing of the gas supply piping system at test
pressure equal to or less than 1/2 psig.
There must be a gas shutoff between the stove
and the supply.
In order to connect Natural Gas, use a fitting with
3/8" NPT nipple on the valve side and 1/2" natural
gas supply line with an input of 28,000 BTUs at a
manifold pressure of 3.5" and minimum inlet
supply for adjustment of 5.5" w.c.
In order to connect Propane, use a fitting with 3/8"
NPT nipple on the valve side and 1/2" propane
gas supply line with an input of 28,000 BTUs at a
manifold pressure of 10.0" and minimum inlet
supply for adjustment of 11.0" w.c.