Vertical Termination - Direct Vent ONLY

A vertical vent system must terminate no less than 8'
(2.44m) and no more than 40' (12m) above the appli-
ance flue collar. A 2¹⁄₄" restrictor plate (supplied) must
be used where specified in all vertically terminated vent
systems. (Fig. 8) NOTE: The restrictor plate sup-
plied with the vertical termination should be dis-
carded. Install restrictor plate supplied with stove
directly at stove outlet. A vertically terminated vent
system must also conform to the following criteria:
• No more than three 90˚ elbows may be used.
• Two 45˚ elbows may be substituted for one 90˚ elbow.
No more than six elbows may be used.
• Vent must rise a minimum of 2 feet before offset is
used.
• Termination height must conform to roof clearance as
specified in Figure 9.
40
39
All Vertical Termi-
38
37
nations in this area
36
Require use of the
35
2¹⁄₄" Restrictor
34
33
Plate*
32
31
30
29
28
27
26
25
Vertical terminations
24
must be within this area
23
22
21
20
19
18
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
1
2
3
4
5
6
7
Horizontal Run (in feet)
Fig. 8 Vertical vent termination window.
*The Restrictor Plate is used on Direct Vent
Installations only.
8
8
Unacceptable
Venting Configuration
8 9
10 11 12 13 14 15 16 17 18 19
Vent Termination Clearances
When planning the installation, consider the location of
the vent terminal and clearances. Some of the most
common clearances to keep in mind are shown in Figure
10.
Important: All vent clearances must be maintained.
Check your vent termination clearances against
Figures 9 through 11.
The vent should be placed so that people cannot be
burned by accidentally touching the vent surfaces
when the stove is operating.
The vent termination should be located where it cannot
be damaged by such things as automobile doors, lawn
mowers or snowblowers and it should be located away
from areas where it could become blocked by snow,
etc.
Some considerations are:
• Obstructions or impediments to venting.
• Nearby combustible materials that could come into
contact with combustion exhaust gases.
• Other nearby openings {within 12" (305mm)} through
which exhaust gas could reenter the building.
• All vegetation within 3' ((76mm) that may interfere
with the draft.
Other factors that influence where the installation will
be sited include the location of outside walls, where
additional heat may be desired in the home, where the
family members gather most regularly, and perhaps
most importantly, the distance limitations of the venting
system.
• The horizontal termination must not be recessed
into the exterior wall or siding.
• Horizontal vent runs must be level toward the
vent termination.
• Clearances around the vent termination must be
maintained.
• For installations using Simpson DuraVent pipe,
parallel installations with minimum wall clearance
have restricted access for connecting the Hori-
zontal Vent Cap straps to the vent pipe. See the
maker's instructions for recommended installa-
tion procedures.
20
ST132a
IMPORTANT
Direct Vent Only
20003456

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents