Function List - Hitachi WJ200-007MF Manual

Pursuing the ideal compact inverter
Table of Contents

Advertisement

Function List

If a desired parameter is not displayed, check the setting of function "b037"(function code display restriction). To display all parameters, specify "00" for "b037".
Code
d001
Output frequency monitoring
d002
Output current monitoring
d003
Rotation direction minitoring
d004
Process variable (PV), PID feedback monitoring
d005
Intelligent input terminal status
d006
Intelligent output terminal status
d007
Scaled output frequency monitoring
d008
Actual-frequency monitoring
d009
Torque command monitoring
d010
Torque bias monitoring
d012
Torque monitoring
d013
Output voltage monitoring
d014
Power monitoring
d015
Cumulative power monitoring
d016
Cumulative operation RUN time monitoring
d017
Cumulative power-on time monitoring
d018
Heat sink temperature monitoring
d022
Life-check monitoring
d023
EzSQ program counter
d024
EzSQ program number
d025
User monitor 1
d026
User monitor 2
d027
User monitor 3
d029
Position setting monitor
d030
Position feedback monitor
d050
Dual monitor
d060
Inverter mode monitor
d080
Trip Counter
d081 – d086 Trip info. 1–6 (factor)
d090
Warning monitor
d102
DC voltage monitoring (across P and N)
d103
BRD load factor monitoring
d104
Electronic thermal overload monitoring
F001
Output frequency setting
F002
Acceleration (1) time setting
F202
Acceleration (1) time setting, 2nd motor
F003
Deceleration (1) time setting
F203
Deceleration (1) time setting, 2nd motor
F004
Keypad Run key routing
A001
Frequency source setting
A201
Frequency source setting, 2nd motor
A002
Run command source setting
A202
Run command source setting, 2nd motor
A003
Base frequency setting
A203
Base frequency setting, 2nd motor
A004
Maximum frequency setting
A204
Maximum frequency setting, 2nd motor
A005
[AT] selection
A011
Pot./O-L input active range start frequency
A012
Pot./O-L input active range end frequency
A013
Pot./O-L input active range start voltage
A014
Pot./O-L input active range end voltage
A015
Pot./O-L input start frequency enable
A016
External frequency filter time constant
A017
Easy sequence function selection
 12
Function Name
0.00 to 99.99 / 100.0 to 400.0 [Hz]
0.0 to 655.3 [A]
F (Forward) / o (Stop) / r (Reverce)
0.00 to 99.99 / 100.0 to 999.9 / 1000. to 9999. / 1000 to 9999 (10000 to 99990) /
100 to 999 (100000 to 999000)
(Example)
7, 5, 3, 1 : ON
6, 4, 2 : OFF
(Example)
11 : ON
AL, 12 : OFF
0.00 to 99.99 / 100.0 to 999.9 / 1000. to 9999. / 1000 to 3999
-400. to -100. / -99.9 to -10.0 / -9.99 to -0.00 / 0.00 to 99.99 / 100.0 to 400.0 [Hz]
-200 to +200 [%]
-200 to +200 [%]
-200 to +200 [%]
0.0 to 600.0 [V]
0.0 to 999.9 [kW]
0.0 to 999.9 / 1000. to 9999. / 1000 to 9999 (10000 to 99990) /
100 to 999 (100000 to 999000)
0. to 9999. / 1000 to 9999 (10000 to 99990) / 100 to 999 (100000 to 999000) [hr]
0. to 9999. / 1000 to 9999 (10000 to 99990) / 100 to 999 (100000 to 999000) [hr]
-20.0 to 150.0 [ ºC]
1: Capacitor on
main circuit board
2: cooling-fan
0 to 1024
0000 to 9999
-2147483647 to 2147483647
-2147483647 to 2147483647
-2147483647 to 2147483647
-268435455 to 268435455
-268435455 to 268435455
Displays two different data configured in b160 and b161.
Displays currently selected inverter mode : I-C / I-V
0 to 65535
Factor code
Warning code
0.0 to 999.9 / 1000. [V]
0.0 to 100.0 [%]
0.0 to 100.0 [%]
0 / "start frequency" to "maximum frequency" [Hz]
0.01 to 99.99 / 100.0 to 999.9 / 1000. to 3600. [s]
0.01 to 99.99 / 100.0 to 999.9 / 1000. to 3600. [s]
0.01 to 99.99 / 100.0 to 999.9 / 1000. to 3600. [s]
0.01 to 99.99 / 100.0 to 999.9 / 1000. to 3600. [s]
00 (Foward) / 01 (Reverce)
00 (keypad potentiometer) / 01 (control circuit terminal block) / 02 (digital operator) /
03 (Modbus) / 04 (option) / 06 (pulse train input) / 07 (easy sequence) /
10 (operation function result)
01 (control circuit terminal block) / 02 (digital operator) /
03 (Modbus) / 04 (option)
30.0 to "maximum frequency (1st)" [Hz]
30.0 to "maximum frequency (2nd)" [Hz]
"Base frequency (1st)" to 400.0 [Hz]
00 (switching between O and OI terminals) /
02 (switching between O terminal and keypad potentiometer) /
03 (switching between OI terminal and keypad potentiometer)
0.00 to 99.99/100.0 to 400.0 [Hz]
0.00 to 99.99/100.0 to 400.0 [Hz]
0 to 100 [%]
0 to 100 [%]
00 (A011) / 01 (0Hz)
1 to 30 / 31
00 (disabled) / 01 (PRG terminal) / 02 (Always)
Setting Range
ON
OFF
ON
OFF
Lifetime expired
Normal
[ ○ = Allowed × = Not parmitted]
Setting During
Change During
Default
Operation
Operation
Setting
(allowed or not)
(allowed or not)
0.00
10.00
10.00
10.00
10.00
×
×
00
×
×
02
×
×
02
×
×
02
×
×
02
×
×
60
×
×
60
×
×
60
×
×
60
×
×
00
×
0.00
×
0.00
×
0
×
100
×
01
×
8
00

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents