Safety Notices - Quadra-Fire DVI-32 Installation, Operation, Venting And Maintenance Instructions

Direct vent gas insert
Table of Contents

Advertisement

This appliance should only be installed by a qualified installer. It is approved for installation in a bedroom. The
appliance must be electrically grounded in accordance with local codes, or the latest edition of the National Electric
Code. If no local codes exist, this appliance should be installed following the current codes:
CAN/CGA-B149.1 .......................................................................... Natural Gas Installation Code
CAN/CGAB149.2 ........................................................................... Liquid Propane Installation Code
CSA-C22.1 ..................................................................................... Canadian Electrical Code
ANSI Z223.1 .................................................................................. National Fuel Gas Code
ANSI NFPA-70 ............................................................................... National Electrical Code
The control compartment, burner, and circulating air passageways MUST be kept clean and clear to allow for
adequate combustion and proper operation. Provide adequate clearances around air openings and adequate
accessibility clearance for service and operation. NEVER obstruct the openings of the appliance or the vent
termination on the exterior of the building. NEVER vent the appliance to other rooms or buildings; this appliance
must be vented ONLY to the outside, with a vertical termination. During installation, be sure to maintain minimum
clearances to combustibles, as shown on page 7. Always contact your local building department or fire department
prior to installing this appliance. If required, obtain a permit before installing, and have the completed installation
inspected. Failure to do this could jeopardize your homeowner's insurance.
The area around the appliance MUST be kept free from combustible materials, gasoline and other flammable
f i r e - p a r t s . c o m
vapors and liquids.
This appliance is hot during operation, and should be located out of heavy traffic areas and away from furniture and
draperies. Clothing or other flammable material should not be placed on or near the appliance. Children and adults
should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing
ignition. Children should not be left unsupervised in the room when this appliance is in operation.
DO NOT USE THIS APPLIANCE: If any part has been under water. Immediately call a qualified service technician
to inspect the appliance, and to replace any part of the control system or any gas control which has been under
water.
This appliance should NOT be modified under any circumstances. Any parts removed for servicing must be replaced
before operating this appliance. Installation and repair should only be done by a qualified service technician. The
appliance and its venting system should be inspected and cleaned annually by a qualified service technician. More
frequent cleaning may be necessary due to excess lint and dust from carpeting, bedding material, etc. Be sure to
turn off gas valve and pilot before cleaning this appliance.
Install at least one smoke detector on each floor of your home to ensure your safety. They should be located away
from the gas appliance and close to the sleeping areas. Follow the smoke detector manufacturer's placement and
installation instructions, and be sure to maintain regularly. Your local fire department may provide assistance in
selecting smoke detectors, or contact the Consumer Product Safety Commission, Washington, D.C. 20207.
250-3692 (11/2000) DVi32 Gas Insert

SAFETY NOTICES