Download Print this page

Contura C i4 Installation Instructions Manual

Insert lit with solid biofuels
Hide thumbs Also See for C i4:

Advertisement

Installation
Instructions
For use in GB and IE only
C i4
www.contura.eu

Advertisement

loading

Summary of Contents for Contura C i4

  • Page 1 Installation Instructions For use in GB and IE only C i4 www.contura.eu...
  • Page 2 See rating plate on the insert Intended area of use Heating of rooms in residential buildings Fuel Wood / (Coal briquettes) MANUFACTURER Name NIBE AB / Contura Address Box 134, Skulptörvägen 10 SE-285 23 Markaryd, Sweden CHECKS According to AVCP System 3...
  • Page 3 A warm welcome to the Contura family. We hope you will get a great deal of pleasure from your new stove. As a new owner of a Contura stove you have secured a product with timeless design and long service life. Contura also has combustion that is both environmentally friendly and efficient for the best heat production.
  • Page 4: Technical Data

    Technical data General Chimney In this manual you will find instructions Note! The stove installation and connection about how your Contura i4 shall be to a chimney must be accomplished with Output 3-5 kW installed. Before you start the installation the current edition of Building Regulations.
  • Page 5 DImENSIONS Dimensions Ci4 Classic 45° Flue outlet 45° backwards Ci4 Modern 3 - sided frame 45° Flue outlet 45° backwards Ci4 Modern 4 - sided frame 45° Flue outlet 45° backwards...
  • Page 6: Heat Shield

    RECESSING THE INSERT Recessing the insert When recessing the insert, adjacent walls that are not classed as fire walls or are considered unsuitable for heat loads must be protected by non-combustible material according to the specification below. All joints on the non-combustible material must be sealed using the manufacture’s recommended method. The area between the insert and the recess must be ventilated according to the specification/dimension.
  • Page 7 RECESS EXAmPLE Recess example Ci4 Classic and Modern The dimensions are the minimum dimensions, unless otherwise stated. Wall of combustible material Wall of non-combustible material, made of 100 mm aerated concrete in the recess example. Wall of non-combustible material that is not in contact with combustible material and therefore has no minimum thickness requirement.
  • Page 8: Hearth Dimensions

    INSTALLATION / COmBUSTION AIR Installation in Builders opening Hearth dimensions The appliance must stand on a constructional hearth which meet the building regulations and has minimum dimension as shown in the diagram beside. Always check that the building has enough bearing capacity for the heart, stove and chimney.
  • Page 9 PREINSTALLATION Prior to installation Remove loose components as stove base plate and ash tray. Take out the stove body from the convection box by first unscrew the four side bolts and the four bolts for the collar. At last release the convection box from the pallet.
  • Page 10 INSTALLING AND CONNECTING Installing and connecting the convection box Flue collar 90° straight upwards or 45° backwards If the builders opening is too tight above when the flue collar adapter plate is turned for installation 45° backwards, then remove and fasten the flue collar adapter on the flue.
  • Page 11 INSTALLING AND CONNECTING Ø 6 mm...
  • Page 12 INSTALLING AND CONNECTING Flue collar 45° backwards and tight builders opening Ø 5 mm...
  • Page 13 SmOKE CONTROL AREA Smoke control area In smoke control areas it is mandatory to stop the damper from closing completely. In other areas it´s optional.
  • Page 14 INSTALLING STOVE BODY Installing stove body into the convection box Classic - fasten the screws properly after the stovebody is fitted to the backpanel Modern - fasten the screws only a few turns, they shall be fasten properly first when the cast iron frame are assembled and fitted, see side 95...
  • Page 15 INSTALLING STOVE BODY Modern frame Make sure that the stovebody and frame are parallel before fasten the screws...
  • Page 16 INSTALLING FIRE PANELS Installing fire box insulation panels The Thermotte insulation panels are fragile, handle them with care and be careful when placing them into the stovebody.
  • Page 17 INSTALLING FIRE PANELS Final inspection of the installation It is very important that the installation is inspected by an authorised chimney sweep before the stove is used. Also read the ”Operating instructions”, before lighting for the first time.
  • Page 20 NIBE AB · Box 134 · 285 23 Markaryd · Sweden www.contura.eu Contura reserves the right to change dimensions and procedures described in these instructions at any 811163 IAV Ci4 SE_EX-5 time without special notice. The current edition can be 2014-02-10 downloaded from www.contura.eu...